AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shabana, W.
Right arrow Articles by De Maeseneer, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shabana, W.
Right arrow Articles by De Maeseneer, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.04.0816
AJR 2006; 186:234-236
© American Roentgen Ray Society


Technical Innovation

Measuring Thyroid Gland Volume: Should We Change the Correction Factor?

Wael Shabana1, Els Peeters1 and Michel De Maeseneer1,2

1 Department of Radiology, AZ-Vrije Universiteit Brussels, Brussels, Belgium.
2 Department of Radiology, University of Michigan Medical Center, 1500 E Medical Center Dr., TC-2910G, Ann Arbor, MI 48109-0326.

OBJECTIVE. In the assessment of thyroid volume with sonography (formula of an ellipsoid), a correction factor is used. Whereas previously 0.524 was used, the World Health Organization has recently changed (after the first review) this correction factor to 0.479. We compare volume measurement of the thyroid using different correction factors to automated volume measurement using MDCT, and we define an optimal correction factor in thyroid volume assessment.

CONCLUSION. Acceptable correction factors are situated in the range of 0.494-0.554. We propose a correction factor of 0.529 when using the ellipsoid formula.

Keywords: correction factor • MDCT screening • thyroid volume