AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schueller, G.
Right arrow Articles by Helbich, T. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schueller, G.
Right arrow Articles by Helbich, T. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.04.1583
AJR 2006; 186:38-43
© American Roentgen Ray Society


Original Research

Image Quality of a Wet Laser Printer Versus a Paper Printer for Full-Field Digital Mammograms

Gerd Schueller1, Elisabeth Kaindl1, Wolfgang K. Matzek1, Friedrich Semturs2, Claudia Schueller-Weidekamm1 and Thomas H. Helbich1

1 Department of Radiology, University Hospital Vienna and Medical University of Vienna, Austria, Waehringer Guertel 18-20/7F, A-1090 Vienna, Austria.
2 Department of Biomedical Engineering and Physics, University Hospital Vienna and Medical University of Vienna, Vienna, Austria.

OBJECTIVE. The purpose of our study was to compare the image quality of a wet laser printer with that of a paper printer for full-field digital mammography (FFDM).

MATERIALS AND METHODS. For both a wet laser printer and a paper printer connected to an FFDM system, image quality parameters were evaluated using a standardized printer test image (luminance density, dynamic range). The detectability of standardized objects on a phantom was also evaluated. Furthermore, 640 mammograms of 80 patients with different breast tissue composition patterns were imaged with both printers. Subjective image quality parameters (brightness, contrast, and detection of details of anatomic structures—that is, skin, subcutis, musculature, glandular tissue, and fat), the detectability of breast lesions (mass, calcifications), and the diagnostic performance according to the BI-RADS classification were evaluated.

RESULTS. Both the luminance density and the dynamic range were superior for the wet laser printer. More standardized objects were visible on the phantom imaged with the wet laser printer than with the paper printer (13/16 vs 11/16). Each subjective image quality parameter of the mammograms from the wet laser printer was rated superior to those of the paper printer. Significantly more breast lesions were detected on the wet laser printer images than on the paper printer images (masses, 13 vs 10; calcifications, 65 vs 48; p < 0.05). With the paper printer images, BI-RADS 4 and 5 categories were underestimated for 10 (43.5%) of 23 patients.

CONCLUSION. For FFDM, images obtained from a wet laser printer show superior objective and subjective image quality compared with a paper printer. As a consequence, the paper printer should not be used for FFDM.

Keywords: digital imaging • full-field digital mammography • mammography • printers


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
radtechHome page
K. A. KHALIFAH, A. BRINDHABAN, G. A. BALOUL, F. A. BATHER, and M. ABDULGAFOOR
Optical Density Changes In Dry-processed Films
Radiol. Technol., September 1, 2007; 79(1): 9 - 16.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. M. Hall
Wet Versus Dry Laser Printers for Copying Digital Mammograms
Am. J. Roentgenol., June 1, 2006; 186(6): E22 - E22.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Schueller
Reply
Am. J. Roentgenol., June 1, 2006; 186(6): E22 - E22.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.