AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yasumoto, T.
Right arrow Articles by Nakamura, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yasumoto, T.
Right arrow Articles by Nakamura, H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.04.1727
AJR 2006; 186:85-89
© American Roentgen Ray Society


Original Research

Assessment of Two 3D MDCT Colonography Protocols for Observation of Colorectal Polyps

Taku Yasumoto1, Takamichi Murakami2, Hiroshi Yamamoto3, Masatoshi Hori2, Riccardo Iannaccone4, Tonsok Kim2, Hisashi Abe2, Masatomo Kuwabara2, Koichi Yamasaki3, Nobuteru Kikkawa5, Hiroshi Arimoto3, Roberto Passariello4 and Hironobu Nakamura2

1 Department of Radiology, Suita Municipal Hospital, Suita, Osaka, Japan.
2 Department of Radiology, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, Osaka 565-0871, Japan.
3 Department of Radiology, Minoh Municipal Hospital, Minoh, Japan.
4 Department of Radiological Sciences, University of Rome, Rome, Italy.
5 Department of Surgery, Minoh Municipal Hospital, Minoh, Japan.

OBJECTIVE. The objective of our study was to assess the value of two-way interpretation (i.e., from rectum to cecum and vice versa) compared with one-way interpretation (i.e., from rectum to cecum only) in terms of polyp detection and interpretation time on MDCT colonography.

MATERIALS AND METHODS. Fifty consecutive patients underwent both CT colonography and conventional colonoscopy. Three radiologists independently analyzed the CT colonographic examinations of each patient using a primary 3D method. All examinations were analyzed using two techniques: navigation from rectum to cecum only (one-way) and navigation from rectum to cecum and vice versa (two-way). Sensitivity and positive predictive value were calculated on both a per-polyp basis and a per-patient basis. Alternative free-response receiver operating characteristic (ROC) curve analysis was estimated, and image interpretation time was documented.

RESULTS. One hundred fifty-five polyps were depicted in 45 patients by colonoscopy. The mean sensitivity of CT colonography for polyp detection with two-way (88.4%) was significantly superior to that with one-way (78.1%) (p < 0.01). The mean positive predictive value of each observer with one-way was 66.7%, whereas that with two-way was 65.8%. The mean area under the alternative free-response ROC curve (Az value) with two-way (0.827) was higher than that with one-way (0.816), but there was not a statistically significant difference. The average interpretation time of each observer with two-way (39 min) was statistically significantly longer than that with one-way (25 min) (p < 0.01).

CONCLUSION. When using a primary 3D interpretation technique at CT colonography, complete 3D navigation from rectum to cecum and from cecum to rectum is mandatory to maximize polyp detection. The image interpretation time for two-way interpretation is statistically significantly longer than that with one-way interpretation.

Keywords: colorectal cancer • CT colonography • MDCT • 3D navigation


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
S. H. Kim, J. M. Lee, H. W. Eun, M. W. Lee, J. K. Han, J. Y. Lee, and B. I. Choi
Two- versus Three-dimensional Colon Evaluation with Recently Developed Virtual Dissection Software for CT Colonography
Radiology, September 1, 2007; 244(3): 852 - 864.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. J. Pickhardt, S. A. Taylor, and S. Halligan
Polyp Detection at CT Colonography: Inadequate Primary 3D Endoluminal Reference Standard Precludes Meaningful Comparison
Radiology, July 1, 2007; 244(1): 316 - 317.
[Full Text] [PDF]


Home page
radtechHome page
D. S. WERDERMAN
CT Colonography
Radiol. Technol., March 1, 2007; 78(4): 309CT - 324CT.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
T. Mang, A. Maier, C. Plank, C. Mueller-Mang, C. Herold, and W. Schima
Pitfalls in Multi-Detector Row CT Colonography: A Systematic Approach
RadioGraphics, March 1, 2007; 27(2): 431 - 454.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.