AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mawlawi, O.
Right arrow Articles by Chasen, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mawlawi, O.
Right arrow Articles by Chasen, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.04.1740
AJR 2006; 186:308-319
© American Roentgen Ray Society


Original Research

Quantifying the Effect of IV Contrast Media on Integrated PET/CT: Clinical Evaluation

Osama Mawlawi1, Jeremy J. Erasmus2, Reginald F. Munden2, Tinsu Pan1, Amy E. Knight2, Homer A. Macapinlac2, Donald A. Podoloff2 and Marvin Chasen2

1 Department of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Box 56, Houston, TX 77030.
2 Department of Diagnostic Radiology, The University of Texas M. D. Anderson Cancer Center, Houston, TX 77030.

OBJECTIVES. The use of IV contrast media in PET/CT can result in an overestimation of PET attenuation factors that potentially can affect interpretation. The objective of this study was to quantify the effect of IV contrast media in PET/CT and assess its impact on patients with intrathoracic malignancies.

MATERIALS AND METHODS. Nine patients had CTs performed with and without IV contrast media followed by 18F-FDG PET. PET images were reconstructed using contrast-enhanced and unenhanced CT. To quantify the effect of contrast media on standardized uptake values (SUV), similar regions of interest (ROIs) were drawn on the subclavian vein, heart, liver, spleen, and site of malignancy on both CT and corresponding reconstructed PET images, and the mean and maximum values were compared. In addition, two physicians blinded to the imaging parameters that were used evaluated the reconstructed PET images to assess whether IV contrast media had an effect on clinical interpretation.

RESULTS. For all patient studies, the subclavian vein region on the ipsilateral side of contrast media administration had the highest increase in CT numbers with a corresponding average SUVmax increase of 27.1%. Similarly, ROIs of the heart and at the site of malignancy showed an increase in the maximum attenuation value with a corresponding average SUVmax increase of 16.7% and 8.4%, respectively. Other locations had relatively small attenuation value differences with a correspondingly negligible SUV variation.

CONCLUSION. Although there is a significant increase in SUV in regions of high-contrast concentration when contrast-enhanced CT is used for attenuation correction, this increase is clinically insignificant. Accordingly, in PET/CT, IV contrast-enhanced CT can be used in combination with the PET to evaluate patients with cancer.

Keywords: artifact • attenuation • contrast media • PET/CT


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JNMHome page
R. Boellaard
Standards for PET Image Acquisition and Quantitative Data Analysis
J. Nucl. Med., May 1, 2009; 50(Suppl_1): 11S - 20S.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Martinez-Moller, M. Souvatzoglou, G. Delso, R. A. Bundschuh, C. Chefd'hotel, S. I. Ziegler, N. Navab, M. Schwaiger, and S. G. Nekolla
Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data
J. Nucl. Med., April 1, 2009; 50(4): 520 - 526.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
M. Allen-Auerbach and W. A. Weber
Measuring Response with FDG-PET: Methodological Aspects
Oncologist, April 1, 2009; 14(4): 369 - 377.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Badiee, B. L. Franc, E. M. Webb, B. Chu, R. A. Hawkins, and F. Coakley
Role of IV Iodinated Contrast Material in 18F-FDG PET/CT of Liver Metastases
Am. J. Roentgenol., November 1, 2008; 191(5): 1436 - 1439.
[Abstract] [Full Text] [PDF]


Home page
Ann OncolHome page
R. L. Elstrom, J. P. Leonard, M. Coleman, and R. K. J. Brown
Combined PET and low-dose, noncontrast CT scanning obviates the need for additional diagnostic contrast-enhanced CT scans in patients undergoing staging or restaging for lymphoma
Ann. Onc., October 1, 2008; 19(10): 1770 - 1773.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D. W. Townsend
Dual-Modality Imaging: Combining Anatomy and Function
J. Nucl. Med., June 1, 2008; 49(6): 938 - 955.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. J. Gollub, R. Hong, D. M. Sarasohn, and T. Akhurst
Limitations of CT During PET/CT
J. Nucl. Med., October 1, 2007; 48(10): 1583 - 1591.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
F. Buther, L. Stegger, M. Dawood, F. Range, M. Schafers, R. Fischbach, T. Wichter, O. Schober, and K. P Schafers
Effective Methods to Correct Contrast Agent-Induced Errors in PET Quantification in Cardiac PET/CT
J. Nucl. Med., July 1, 2007; 48(7): 1060 - 1068.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Z. Wong, E. K. Paulson, R. C. Nelson, E. F. Patz Jr., and R. E. Coleman
Practical Approach to Diagnostic CT Combined with PET
Am. J. Roentgenol., March 1, 2007; 188(3): 622 - 629.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. A. Weber and R. Figlin
Monitoring Cancer Treatment with PET/CT: Does It Make a Difference?
J. Nucl. Med., January 1, 2007; 48(1_suppl): 36S - 44S.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Brechtel and T. Beyer
Reply: Adequate Evaluation of Image Registration in Hybrid PET/CT.
J. Nucl. Med., September 1, 2006; 47(9): 1557 - 1558.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.