AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Armato, S. G.
Right arrow Articles by MacMahon, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Armato, S. G., III
Right arrow Articles by MacMahon, H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.05.0076
AJR 2006; 186:1000-1006
© American Roentgen Ray Society


Original Research

Variability in Mesothelioma Tumor Response Classification

Samuel G. Armato, III1, Joseph L. Ogarek1, Adam Starkey1, Nicholas J. Vogelzang2, Hedy L. Kindler3, Masha Kocherginsky4 and Heber MacMahon1

1 Department of Radiology, The University of Chicago, 5841 S Maryland Ave., Chicago, IL 60637.
2 Nevada Cancer Institute, Las Vegas, NV 89135.
3 Department of Medicine, The University of Chicago, Chicago, IL 60637.
4 Department of Health Studies, The University of Chicago, Chicago, IL 60637.

OBJECTIVE. The objective of our study was to evaluate observer variability in the measurement of temporal change in mesothelioma tumor thickness and in the resulting tumor response classification from CT scans. In addition, the performance of a semiautomated measurement method was evaluated.

MATERIALS AND METHODS. Four observers individually used an interface that displayed two serial CT scans from the same patient to measure mesothelioma tumor thickness on the follow-up CT scans of 22 patients based on baseline scan measurements. During one session, observers acquired measurements on the follow-up scans based on written reports of baseline scan measurements; in another session, baseline scan measurements were superimposed on the baseline scan for direct visual comparison. Follow-up scan measurements also were obtained from a semiautomated method. Measurement variability and tumor response classification concordance were evaluated for manual measurements acquired in both modes and for semiautomated measurements.

RESULTS. Although only a small increase in tumor response classification concordance rate was obtained with the visual approach (84.8%) relative to the more standard written-report approach (82.6%), the actual measurements acquired by observers were statistically significantly different between the two approaches (p = 0.03). Both the semiautomated measurements and the resulting tumor response classifications were consistent with manual measurements.

CONCLUSION. The presentation of baseline scan tumor measurements affects measurements acquired on follow-up scans and could influence tumor response classification. The potential utility of semiautomated tumor thickness measurements was shown in the context of measuring tumor response.

Keywords: computer-aided diagnosis • CT • lung cancer • mesothelioma • oncologic imaging • tumor response


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.