AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MacCarty, R. L.
Right arrow Articles by Wilson, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MacCarty, R. L.
Right arrow Articles by Wilson, L. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.05.0031
AJR 2006; 186:1380-1383
© American Roentgen Ray Society


Original Research

Occult Colorectal Polyps on CT Colonography: Implications for Surveillance

Robert L. MacCarty1, C. Daniel Johnson1, Joel G. Fletcher1 and Lynn A. Wilson1

1 All authors: Mayo Clinic, Mayo Medical School, Mary Clinic E-2, 200 First St. SW, Rochester, MN 55905.

OBJECTIVE. Our purpose was to determine the prevalence of polyps that are invisible on CT colonography (CTC) in a population previously screened for colorectal neoplasms. Differences in the prevalence of occult polyps in various populations might help explain the discordant reported sensitivities for polyp detection in published reports of CTC.

SUBJECTS AND METHODS. Seventy-five consecutive patients who had been previously screened for polyps underwent same-day colonoscopy and CTC. Many of the patients had personal histories of previous polypectomies and were undergoing surveillance colonoscopy. The scans were interpreted prospectively by an experienced radiologist. Polyps missed prospectively on CTC were analyzed retrospectively by three experienced radiologists and categorized as perception errors (visible in retrospect), technical errors (e.g., obscured by feces or fluid), or occult (invisible).

RESULTS. Thirty polyps 5 mm or larger were found at colonoscopy, 18 of which were missed prospectively on CTC. Of the 18 missed polyps, 12 could not be identified in retrospect, even though they were located in clean, dry, well-distended colonic segments. These were classified as occult. Ten of the 12 occult polyps showed flat morphology on review of colonoscopy video recordings. Of the remaining six missed polyps, two were classified as perception errors, two as technical errors, and two as a combination of technical and perception error.

CONCLUSION. In this population, colonographically occult polyps were common and accounted for more detection failures than perception errors and technical errors combined. The high prevalence of occult polyps may be explained by the fact that previous screening may have led to removal of easy-to-see polyps, creating a study population with a higher percentage of hard-to-see polyps.

Keywords: colonography • colorectal cancer • CT • polyps


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
P. J. Pickhardt and D. H. Kim
Colorectal Cancer Screening With CT Colonography: Key Concepts Regarding Polyp Prevalence, Size, Histology, Morphology, and Natural History
Am. J. Roentgenol., July 1, 2009; 193(1): 40 - 46.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. H. Park, S. Y. Kim, S. S. Lee, L. Bogoni, A. Y. Kim, S.-K. Yang, S.-J. Myung, J.-S. Byeon, B. D. Ye, and H. K. Ha
Sensitivity of CT Colonography for Nonpolypoid Colorectal Lesions Interpreted by Human Readers and With Computer-Aided Detection
Am. J. Roentgenol., July 1, 2009; 193(1): 70 - 78.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Jensch, A. H. de Vries, J. Peringa, S. Bipat, E. Dekker, L. C. Baak, J. F. Bartelsman, A. Heutinck, A. D. Montauban van Swijndregt, and J. Stoker
CT Colonography with Limited Bowel Preparation: Performance Characteristics in an Increased-Risk Population
Radiology, April 1, 2008; 247(1): 122 - 132.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. T. Johnson, J. G. Fletcher, and C. D. Johnson
Computer-Aided Detection (CAD) Using 360{degrees} Virtual Dissection: Can CAD in a First Reviewer Paradigm Be a Reliable Substitute for Primary 2D or 3D Search?
Am. J. Roentgenol., October 1, 2007; 189(4): W172 - W176.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.