AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shinners, T. J.
Right arrow Articles by Olsen, C. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shinners, T. J.
Right arrow Articles by Olsen, C. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.05.0416
AJR 2006; 186:1491-1496
© American Roentgen Ray Society


Original Research

Patient-Controlled Room Air Insufflation Versus Automated Carbon Dioxide Delivery for CT Colonography

Theodore J. Shinners1,2, Perry J. Pickhardt1,3, Andrew J. Taylor1, Debra A. Jones1 and Cara H. Olsen4

1 Department of Radiology, University of Wisconsin Medical School, Clinical Science Center, 600 Highland Ave., Madison, WI 53792.
2 Ministry Health-St. Mary's Hospital, Rhinelander, WI 54501.
3 Department of Radiology, Uniformed Services University of the Health Sciences, Bethesda, MD.
4 Biostatistics Consulting Center, Uniformed Services University of the Health Sciences, Bethesda, MD.

OBJECTIVE. Our objective was to prospectively compare colonic distention and patient comfort at screening CT colonography (CTC) with patient-controlled room air (RA) insufflation versus automated carbon dioxide (CO2) delivery.

SUBJECTS AND METHODS. Two hundred eight adults undergoing CTC were randomized to RA or CO2 (104 per method). Colonic distention was prospectively assessed by segment using a 4-point scale (1 = optimal, 2 = adequate, 3 = inadequate, 4 = collapsed). Adequacy of combined supine/prone segmental evaluation was also recorded. Patients provided discomfort ratings on a 0-10 scale (0-1 = none/insignificant, 2-3 = minimal, 4-6 = intermediate, 7-10 = significant) before, during, and after the procedure.

RESULTS. No significant differences in segmental distention were observed in the prone position between techniques. In the supine position, CO2 resulted in significantly greater distention in the sigmoid, descending, and transverse segments (p < 0.01). After combined supine/prone assessment, two/104 (1.9%) and three/104 (2.9%) patients were judged to have an inadequately evaluated segment on RA and CO2, respectively (four sigmoid, one transverse). Mean discomfort scores for RA and CO2 were 3.97 and 5.08 during the examination (p < 0.01); 0.91 and 0.42 immediately after (p < 0.01); 0.51 and 0.25 15 min later (p < 0.05); and 0.15 and 0.04 2 hours later (p < 0.01), respectively. During active distention, 19 (18.3%) and 33 (31.7%) patients reported significant transient discomfort with RA and CO2, respectively (p < 0.05). Beyond 15 min, only two (1.9%) patients with RA and no patients with CO2 had a discomfort level higher than 3.

CONCLUSION. Although patient-controlled RA insufflation and automated CO2 delivery each resulted in negligible postprocedure discomfort and reliable colonic distention, CO2 was better for both categories.

Keywords: colon • CT colonography • CT technique • screening


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
R. L. Van Uitert, R. M. Summers, J. M. White, K. K. Deshpande, J. R. Choi, and P. J. Pickhardt
Temporal and Multiinstitutional Quality Assessment of CT Colonography
Am. J. Roentgenol., November 1, 2008; 191(5): 1503 - 1508.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. M. Summers, L. R. Handwerker, P. J. Pickhardt, R. L. Van Uitert, K. K. Deshpande, S. Yeshwant, J. Yao, and M. Franaszek
Performance of a Previously Validated CT Colonography Computer-Aided Detection System in a New Patient Population
Am. J. Roentgenol., July 1, 2008; 191(1): 168 - 174.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Y. Kim, S. H. Park, E. K. Choi, S. S. Lee, K. H. Lee, J. C. Kim, C. S. Yu, H. C. Kim, A. Y. Kim, and H. K. Ha
Automated Carbon Dioxide Insufflation for CT Colonography: Effectiveness of Colonic Distention in Cancer Patients with Severe Luminal Narrowing
Am. J. Roentgenol., March 1, 2008; 190(3): 698 - 706.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. K. Deshpande, R. M. Summers, R. L. Van Uitert, M. Franaszek, L. Brown, A. J. Dwyer, J. G. Fletcher, J. R. Choi, and P. J. Pickhardt
Quality Assessment for CT Colonography: Validation of Automated Measurement of Colonic Distention and Residual Fluid
Am. J. Roentgenol., December 1, 2007; 189(6): 1457 - 1463.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. J. Pickhardt
Screening CT Colonography: How I Do It
Am. J. Roentgenol., August 1, 2007; 189(2): 290 - 298.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
T. Mang, A. Maier, C. Plank, C. Mueller-Mang, C. Herold, and W. Schima
Pitfalls in Multi-Detector Row CT Colonography: A Systematic Approach
RadioGraphics, March 1, 2007; 27(2): 431 - 454.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. J. Pickhardt, A. J. Taylor, D. H. Kim, M. Reichelderfer, D. V. Gopal, and P. R. Pfau
Screening for Colorectal Neoplasia with CT Colonography: Initial Experience from the 1st Year of Coverage by Third-Party Payers
Radiology, November 1, 2006; 241(2): 417 - 425.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.