Original Research |
1 Department of Clinical Radiology, University of Muenster,
Albert-Schweitzer-Straße 33, D-48149 Muenster, Germany.
2 Department of Cardiology and Angiology, University of Muenster, Muenster,
Germany.
OBJECTIVE. Determination of left ventricular (LV) volumes and global function parameters from MDCT data sets is usually based on short-axis reformations from primarily reconstructed axial images, which prolong postprocessing time. The aim of this study was to evaluate the feasibility of LV volumetry and global LV function assessment from axial images in comparison with short-axis image reformations.
SUBJECTS AND METHODS. This study consisted of 20 patients with either coronary artery disease or dilated cardiomyopathy. We evaluated MDCT results using cine MRI as the reference technique.
RESULTS. LV end-diastolic volume (LVEDV) and end-systolic volume (LVESV) were significantly overestimated by the axial MDCT approach in comparison with volume measurements from short-axis CT image reformations. The mean LV ejection fraction (LVEF) was not significantly different (41.2% vs 42.7%). Short-axis and axial MDCT determination of LVEF revealed a systematic underestimation by a mean ± SD of -2.1% ± 3.6% versus -3.6% ± 8.2%, respectively, when compared with LVEF values based on cine MRI. The interobserver variability for volume and function measurements from axial images (LVEDV = 8.5%, LVESV = 10.8%, LVEF = 9.6%) was slightly higher than those measurements from short-axis reformations (LVEDV = 7.2%, LVESV = 9.5%, LVEF = 8.7%). The mean total evaluation time was significantly shorter using axial images (14.1 ± 3.9 min) compared with short-axis reformations (16.9 ± 5.2 min) (p < 0.05).
CONCLUSION. Determination of LV volumes and assessment of global LV function from axial MDCT image reformations is feasible and time efficient. This approach might be a clinically useful alternative to established short-axis-based measurements in patients with normal or near-normal LV function. A progressive underestimation of LVEF with increasing LV volumes may limit the clinical applicability of the axial approach in patients with dilated cardiomyopathy.
Keywords: axial image reformations cine MRI left ventricular function MDCT semiautomated MDCT data analysis
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
K. U. Juergens, H. Seifarth, F. Range, S. Wienbeck, M. Wenker, W. Heindel, and R. Fischbach Automated Threshold-Based 3D Segmentation Versus Short-Axis Planimetry for Assessment of Global Left Ventricular Function with Dual-Source MDCT Am. J. Roentgenol., February 1, 2008; 190(2): 308 - 314. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Nakayama, M. Asano, K. Matsumoto, N. Nomura, T. Saito, A. Mizuno, and A. Mishima Reconstruction of the Right Heart in an Elderly Woman With Ebstein's Anomaly and Severe Heart Failure Ann. Thorac. Surg., November 1, 2007; 84(5): 1745 - 1746. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Brodoefel, U. Kramer, A. Reimann, C. Burgstahler, S. Schroeder, A. Kopp, and M. Heuschmid Dual-Source CT with Improved Temporal Resolution in Assessment of Left Ventricular Function: A Pilot Study Am. J. Roentgenol., November 1, 2007; 189(5): 1064 - 1070. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Gibbons, P. A. Araoz, and E. E. Williamson The Year in Cardiac Imaging J. Am. Coll. Cardiol., September 4, 2007; 50(10): 988 - 1003. [Full Text] [PDF] |
||||
![]() |
P. M. Colletti Cardiac Imaging 2006 Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S337 - S340. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |