AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Revel, M.-P.
Right arrow Articles by Frija, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Revel, M.-P.
Right arrow Articles by Frija, G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.05.1228
AJR 2006; 187:135-142
© American Roentgen Ray Society


Original Research

Software Volumetric Evaluation of Doubling Times for Differentiating Benign Versus Malignant Pulmonary Nodules

Marie-Pierre Revel1,2,3, Aurelie Merlin1,2,3, Severine Peyrard1,4, Rached Triki1,2,3, Sophie Couchon1,2,3, Gilles Chatellier1,2,5 and Guy Frija1,2,3

1 Département de Radiologie, Assistance Publique des Hôpitaux de Paris, 20 rue Leblanc, Paris, F-75015 France.
2 Université Paris-Descartes, Faculté de Médecine, Paris, F-75015 France.
3 Département de Radiologie, Hôpital Européen Georges Pompidou, Paris, F-75015 France.
4 Centre d'Investigations Cliniques, Hôpital Européen George Pompidou, Paris, F-75015 France.
5 Unité de Recherché Clinique, Hôpital Européen George Pompidou, Paris, F-75015 France.

OBJECTIVE. The purpose of our study was to evaluate the reliability of software-calculated doubling times for discerning malignant versus benign nodules.

MATERIALS AND METHODS. CT lung analysis volumetric software was used to retrospectively calculate the doubling times of 63 solid noncalcified nodules by comparing nodule volumes on baseline and follow-up CT scans obtained a median of 3.7 months apart. A final diagnosis based on validated criteria was available for all 63 nodules. All CT examinations were performed with 1.25-mm-thick slices on a four-detector unit. Taking 500 days as the upper value for malignancies, we evaluated whether the software-calculated doubling times could be used to distinguish malignant from benign solid nodules. We also examined whether the relative volume variation of benign nodules correlated with initial nodule size, interscan interval, or differences in contrast administration or exposure parameters between baseline and follow-up CT.

RESULTS. There were 52 benign and 11 malignant nodules. Benign nodules had a median doubling time of 947 days and a mean relative volume variation of -4.4% (range, -50% to 38%). Malignant nodules had a median doubling time of 117 days and a mean relative volume variation of 102% (22-462%). The sensitivity, specificity, and negative and positive predictive values of the volumetric software for diagnosing malignancy were 91% (95% confidence interval [CI], 0.59-1.00), 90% (95% CI, 0.79-0.97), 98% (95% CI, 0.89-1.00), and 67% (95% CI, 0.38-0.88), respectively. No correlation was found between the relative volume variation of benign nodules and their initial size, the interscan interval, or differences in contrast administration or exposure parameters between the two CT examinations.

CONCLUSION. Software-calculated pulmonary nodule doubling times of more than 500 days have a 98% negative predictive value for the diagnosis of solid malignant pulmonary nodules. This method may be useful for diagnosing malignant pulmonary nodules on follow-up CT.

Keywords: chest • comparative studies • computer applications—3D • CT • lung • lung cancer • MDCT • oncologic imaging


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. Beigelman-Aubry, P. Raffy, W. Yang, R. A. Castellino, and P. A. Grenier
Computer-Aided Detection of Solid Lung Nodules on Follow-Up MDCT Screening: Evaluation of Detection, Tracking, and Reading Time
Am. J. Roentgenol., October 1, 2007; 189(4): 948 - 955.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.