AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berns, E. A.
Right arrow Articles by Willis, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berns, E. A.
Right arrow Articles by Willis, L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.05.1397
AJR 2006; 187:38-41
© American Roentgen Ray Society


Original Research

Digital and Screen-Film Mammography: Comparison of Image Acquisition and Interpretation Times

Eric A. Berns1, R. Edward Hendrick1, Mariana Solari1, Lora Barke1, Denise Reddy1, Judith Wolfman1, Lewis Segal1, Patricia DeLeon1, Stefanie Benjamin1 and Laura Willis1

1 All authors: Lynn Sage Comprehensive Breast Center, Northwestern Memorial Hospital, Chicago, IL 60611; and Department of Radiology, Northwestern University Feinberg School of Medicine, 251 E Huron St., Galter Pavilion, 13th Fl., Chicago, IL 60611.

OBJECTIVE. The objective of our study was to compare acquisition times and interpretation times of screening examinations using screen-film mammography and soft-copy digital mammography.

MATERIALS AND METHODS. Technologist study acquisition time from examination initiation to release of the screenee was measured for both screen-film and digital mammography (100 cases each) in routine clinical practice. The total interpretation time for screening mammography was also measured for 183 hard-copy screen-film cases and 181 soft-copy digital cases interpreted by a total of seven breast imaging radiologists, four experienced breast imagers, and three breast imaging fellows.

RESULTS. Screening mammography acquisition time averaged 21.6 minutes for screen-film and 14.1 minutes for digital, a highly significant 35% shorter time for digital than screen-film (p < 10-17). The average number of images per case acquired with digital mammography was higher than that for screen-film mammography (4.23 for screen-film, 4.50 for digital; p = 0.047). The total interpretation time averaged 1.4 minutes for screen-film mammography and 2.3 minutes for digital mammography, a highly significant 57% longer interpretation time for digital (p < 10-11). In addition, technical problems delaying interpretation were encountered in none of the 183 screen-film cases but occurred in nine (5%) of the 181 digital cases.

CONCLUSION. Compared with screen-film mammography, the use of digital mammography for screening examinations significantly shortened acquisition time but significantly increased interpretation time. In addition, more technical problems were encountered that delayed the interpretation of digital cases.

Keywords: breast cancer • digital imaging • digital mammography • mammography • screen-film mammography • screening