Original Research |
1 Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido,
Gifu 501-1194, Japan.
2 Department of Radiology Services, Gifu University School of Medicine, Gifu,
Japan.
3 Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka,
Japan.
4 Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo,
Japan.
OBJECTIVE. The purpose of our study was to determine the optimal scan delays required for hepatic arterial and portal venous phase imaging and for the detection of hypervascular hepatocellular carcinomas (HCCs) in contrast-enhanced MDCT of the liver using a bolus-tracking program.
SUBJECTS AND METHODS. CT images (2.5-mm collimation, 5-mm thickness with no intersectional gap) detected an increase in the CT value of 50 H in the lower thoracic aorta. The images were obtained after an IV bolus injection of 2 mL/kg of nonionic iodine contrast material (300 mg I/mL) at 4 mL/s in 171 patients, who were prospectively randomized into three groups with scans commencing at 5, 20, and 45 seconds; 10, 25, and 50 seconds; and 15, 30, and 55 seconds for the first (acquisition time: 4.3 seconds), second (4.3 seconds), and third (9.1 seconds) phases, respectively, after a bolus-tracking program. CT values of the aorta, spleen, proximal portal veins, liver parenchyma, and hepatic veins were measured. Increases in CT values from unenhanced to contrast-enhanced CT were assessed using a contrast enhancement index (CEI). Spleen-to-liver and HCC-to-liver contrasts were also assessed. A qualitative degree of contrast enhancement in each organ was prospectively assessed by two independent radiologists.
RESULTS. At 10-15 seconds, the CEI of the aorta reached 300-336 H and that of the spleen reached 97-108 H without significant enhancement of liver parenchyma (15-25 H). The CEI of the proximal portal veins moderately increased (75-104 H) at 10-15 seconds, but no significant enhancement of hepatic veins was observed (24-51 H). The CEI of liver parenchyma peaked (59-63 H) at 45-55 seconds, when the CEIs of the aorta (117-125 H) and spleen (73-82 H) decreased. Spleen-to-liver contrast (81-84 H) was highest at 10-20 seconds and HCC-to-liver contrast (39-44 H) was highest at 10-15 seconds. The qualitative results correlated well with quantitative results.
CONCLUSION. The optimal scan delays for hepatic arterial and portal venous phases after the bolus-tracking program detected threshold enhancement by 50 H in the lower thoracic aorta for the detection of hypervascular HCCs were 10-15 and 45-55 seconds, respectively.
Keywords: contrast media CT technique liver
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
D. T. Boll and E. M. Merkle Diffuse Liver Disease: Strategies for Hepatic CT and MR Imaging RadioGraphics, October 1, 2009; 29(6): 1591 - 1614. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kondo, M. Kanematsu, S. Goshima, Y. Tomita, T. Miyoshi, A. Hatcho, N. Moriyama, M. Onozuka, Y. Shiratori, and K. T. Bae Abdominal Multidetector CT in Patients with Varying Body Fat Percentages: Estimation of Optimal Contrast Material Dose Radiology, December 1, 2008; 249(3): 872 - 877. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Yanaga, K. Awai, T. Nakaura, T. Namimoto, S. Oda, Y. Funama, and Y. Yamashita Optimal Contrast Dose for Depiction of Hypervascular Hepatocellular Carcinoma at Dynamic CT Using 64-MDCT Am. J. Roentgenol., April 1, 2008; 190(4): 1003 - 1009. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kanematsu, S. Goshima, H. Kondo, K. T. Bae, K. Awai, and Y. Yamashita How Should We Optimize Bolus Tracking with Multidetector CT of the Abdomen? Radiology, February 1, 2008; 246(2): 643 - 645. [Full Text] [PDF] |
||||
![]() |
L. L. Chu, B. N. Joe, A. C. A. Westphalen, E. M. Webb, F. V. Coakley, and B. M. Yeh Patient-specific Time to Peak Abdominal Organ Enhancement Varies with Time to Peak Aortic Enhancement at MR Imaging Radiology, December 1, 2007; 245(3): 779 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Heilmaier, R. Sutter, A. M. Lutz, B. Seifert, D. Weishaupt, B. Marincek, and J. K. Willmann Mapping of Hepatic Vascular Anatomy: Dynamic Contrast-enhanced Parallel MR Imaging Compared with 64 Detector Row CT Radiology, December 1, 2007; 245(3): 872 - 880. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |