Original Research |
1 Department of Radiology, Medical University Graz, 8036 Graz, Austria.
2 Institute for Medical Informatics, Statistics and Documentation, Medical
University Graz, 8036 Graz, Austria.
3 Diagnostikum Graz Sued West, Weblinger Guertel 25, 8054 Graz, Austria.
OBJECTIVE. The purpose of this study was to assess whether body weight, body mass index, and scan length influence arterial enhancement during CT angiography (CTA) of the pulmonary arteries at different iodine flow rates.
MATERIALS AND METHODS. CTA examinations of the pulmonary arteries performed for routine clinical care of 120 patients between March and December 2003 were retrospectively evaluated. Patients had received either 120 mL of contrast medium with an iodine concentration of 300 mg I/mL (group A) or 90 mL of contrast medium with an iodine concentration of 400 mg I/mL (group B). The iodine dose was 36 g, and the injection rate was 4 mL/s in all examinations. The iodine flow rate was 1.2 g I/s in group A and 1.6 g I/s in group B. Arterial attenuation along the z-axis was measured per patient, and the influence of body weight, body mass index, and scan length on enhancement of the pulmonary arteries in the two groups was assessed.
RESULTS. In group A and in group B, body weight and body mass index correlated significantly with mean enhancement along the z-axis (r = -0.35 and -0.26 for group A and -0.48 and -0.40 for group B). Scan length showed no correlation with pulmonary attenuation. Mean pulmonary artery enhancement was significantly higher in group B with a difference of 51 H compared with group A.
CONCLUSION. Pulmonary artery attenuation in CTA of the pulmonary arteries shows a small but significant correlation with body weight and body mass index independently of the iodine flow rate used. A higher iodine flow rate improves pulmonary artery enhancement.
Keywords: arteries body mass index body weight CT angiography IV contrast agents thorax
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
Y. Yanaga, K. Awai, T. Nakaura, S. Oda, Y. Funama, K. T. Bae, and Y. Yamashita Effect of Contrast Injection Protocols with Dose Adjusted to the Estimated Lean Patient Body Weight on Aortic Enhancement at CT Angiography Am. J. Roentgenol., April 1, 2009; 192(4): 1071 - 1078. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Roggenland, S. A. Peters, S. P. Lemburg, T. Holland-Letz, V. Nicolas, and C. M. Heyer CT Angiography in Suspected Pulmonary Embolism: Impact of Patient Characteristics and Different Venous Lines on Vessel Enhancement and Image Quality Am. J. Roentgenol., June 1, 2008; 190(6): W351 - W359. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |