AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gluecker, T. M.
Right arrow Articles by Bilecen, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gluecker, T. M.
Right arrow Articles by Bilecen, D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.05.1007
AJR 2006; 187:905-910
© American Roentgen Ray Society


Original Research

MR Angiography of the Hand with Subsystolic Cuff-Compression Optimization of Injection Parameters

Thomas M. Gluecker1, Georg Bongartz1, Hans Peter Ledermann1 and Deniz Bilecen1

1 All authors: Department of Diagnostic Radiology, University Hospital Basel, Petersgraben 4, Basel, Switzerland 4032.

OBJECTIVE. The purpose of our study was to assess the impact of various injection rates on contrast-enhanced high-resolution 3D MR angiography of the hand.

MATERIALS AND METHODS. Ten healthy individuals (mean age, 24.4 years; range, 20-27 years) underwent 3D contrast-enhanced MR angiography of both hands. Starting 3 minutes before data acquisition, subsystolic upper arm cuff compression was applied unilaterally. A 1.5-T whole-body scanner with 3D gradient-echo sequence was used. Seven data sets (20 seconds) were obtained consecutively. IV contrast material of 0.1 mg/kg of body weight of gadobutrol was injected at rates of 0.5, 1.0, and 1.5 mL/s. For both hands, quantitative data evaluation was performed with contrast-to-noise ratio (CNR) in the radial, ulnar, palmar, and digital arteries and veins. Qualitative assessment of the arterial visualization score and venous contamination score was rated by two experienced radiologists using a 4-point scale.

RESULTS. The lowest venous contamination score (CNR and reviewers' assessment) was observed with an injection rate of 0.5 mL/s (p < 0.05). For the arterial signal, the reviewers' assessment was that an injection rate of 0.5 mL/s was best (p = 0.08). Compression yielded a significantly lower venous contamination score for the compressed side than for the noncompressed side for flow rates of 0.5 mL/s and 1.0 mL/s (p < 0.05).

CONCLUSION. Image quality of hand MR angiography was better with cuff compression. A flow rate of 0.5 mL/s yielded a good CNR and a significantly lower venous contamination score than the other flow rates.

Keywords: contrast media • hand • MR angiography • musculoskeletal imaging


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
R. P. Lim, P. Storey, I. P. Atanasova, J. Xu, E. M. Hecht, J. S. Babb, D. R. Stoffel, H. Chang, K. McGorty, Q. Chen, et al.
Three-dimensional Electrocardiographically Gated Variable Flip Angle FSE Imaging for MR Angiography of the Hands at 3.0 T: Initial Experience
Radiology, September 1, 2009; 252(3): 874 - 881.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.