Original Research |
1 Department of Radiology, University of Occupational and Environmental Health,
School of Medicine, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu 807-8555,
Japan.
2 Department of Radiology, School of Health Sciences, Kumamoto University,
Kumamoto, Japan.
3 Department of Radiology, Kurt Rossmann Laboratories for Radiologic Image
Research, The University of Chicago, Chicago, IL.
OBJECTIVE. Our purpose was to compare reviewing time and diagnostic accuracy in the interpretation of radiographs without and with subtraction images and to examine whether this temporal subtraction technique can contribute to improving radiologists' performance.
MATERIALS AND METHODS. Thirty cases with newly developed chest abnormalities on chest radiographs and 90 negative cases were selected. All chest radiographs were obtained with a computed radiography system. For the 90 negative cases, subtraction images were classified into two groups: 33 clean images without misregistration artifacts and 57 images with some misregistration artifacts. Eight radiologists (four board-certified radiologists and four radiology residents) participated in observer tests and interpreted the original radiographs without and with subtraction images using an independent test method. The reviewing time for each radiologist was recorded in each case. The observers' performance was evaluated by use of receiver operating characteristic (ROC) analysis.
RESULTS. When subtraction images were available, the mean reviewing time per case was reduced significantly from 13.6 to 10.8 seconds for the cases with newly developed abnormalities (p < 0.001) and from 29.8 to 14.1 seconds for negative cases (p < 0.001). The reduction in the mean reviewing time with subtraction images was greater for clean images than for images with artifacts (17.7 vs 14.5 seconds, p < 0.001). The average mean area under the ROC curve value increased significantly from 0.942 without subtraction images to 0.988 with subtraction images (p = 0.025). There were significant differences in the sensitivity (0.963 with and 0.888 without the subtraction images) and the specificity (0.976 with and 0.899 without the subtraction images) (p < 0.001).
CONCLUSION. The temporal subtraction technique can reduce reviewing time and also improve diagnostic accuracy in the interpretation of chest radiographs.
Keywords: diagnostic radiology digital radiography lung disease receiver operating characteristic (ROC) reviewing time temporal subtraction
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
F. Girvin and J. P. Ko Pulmonary Nodules: Detection, Assessment, and CAD Am. J. Roentgenol., October 1, 2008; 191(4): 1057 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Li, R. Engelmann, K. Doi, and H. MacMahon Improved Detection of Small Lung Cancers with Dual-Energy Subtraction Chest Radiography Am. J. Roentgenol., April 1, 2008; 190(4): 886 - 891. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kakeda, Y. Korogi, H. Arimura, T. Hirai, S. Katsuragawa, T. Aoki, and K. Doi Diagnostic Accuracy and Reading Time to Detect Intracranial Aneurysms on MR Angiography Using a Computer-Aided Diagnosis System Am. J. Roentgenol., February 1, 2008; 190(2): 459 - 465. [Abstract] [Full Text] [PDF] |
||||