AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sanelli, P. C.
Right arrow Articles by Zimmerman, R. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sanelli, P. C.
Right arrow Articles by Zimmerman, R. D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.05.2188
AJR 2007; 188:213-218
© American Roentgen Ray Society


Original Research

Reproducibility of Postprocessing of Quantitative CT Perfusion Maps

Pina C. Sanelli1, Gregory Nicola1, Apostolos J. Tsiouris1, Igor Ougorets2, Charles Knight1, Bruce Frommer1, Steve Veronelli1 and Robert D. Zimmerman1

1 Department of Radiology, New York Presbyterian Hospital, Weill Medical College of Cornell University, 520 E 70th St., Starr 630, New York, NY 10021.
2 Department of Neurology, New York Presbyterian Hospital, Weill Medical College of Cornell University, New York, NY 10021.

OBJECTIVE. The purpose of this study was to assess interobserver and intraobserver variability in evaluation of the reproducibility of quantitative data obtained in semiautomated postprocessing of CT perfusion data sets by observers of different levels of skill and experience and in fully automated postprocessing.

MATERIALS AND METHODS. Twenty CT perfusion data sets were postprocessed by a neuroradiologist using an automated postprocessing program and by five observers (neuroradiology attending, neurology attending, radiology resident, senior and junior CT technologists) who received a brief training session in use of software for semiautomated postprocessing. For assessment of intraobserver variability, each observer repeated postprocessing of 10 CT perfusion data sets. Standard regions of interest were placed on identical locations for each observer's cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps of three brain regions: an ischemia-infarct region, normal cortical gray matter, and white matter.

RESULTS. The variability in mean quantitative values of CBF, CBV, and MTT was 2.5-9.5% among all observers. Greater variability (20.4%) was introduced with the automated program. High correlation was found among all possible pairings of observers (r = 0.87-0.99). Low correlation was observed between automated postprocessing and postprocessing by all observers. Intraobserver variability in quantitative CT perfusion data ranged from 0.29% to 10.8%. High intraobserver correlation (r = 0.91-0.99) was found for the observers.

CONCLUSION. Quantitative CBF, CBV, and MTT data obtained from postprocessing of CT perfusion data sets are reproducible among observers with varying levels of skill and experience. Observer interaction with the software is an important component for correct identification of user-defined parameters. Establishing a uniform and standard postprocessing technique is essential for maintaining good reproducibility.

Keywords: brain • cerebrovascular disease • CT • perfusion CT


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J. Wang, N. Wu, M. D. Cham, and Y. Song
Tumor Response in Patients With Advanced Non-Small Cell Lung Cancer: Perfusion CT Evaluation of Chemotherapy and Radiation Therapy
Am. J. Roentgenol., October 1, 2009; 193(4): 1090 - 1096.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.S. Vagal, J.L. Leach, M. Fernandez-Ulloa, and M. Zuccarello
The Acetazolamide Challenge: Techniques and Applications in the Evaluation of Chronic Cerebral Ischemia
AJNR Am. J. Neuroradiol., May 1, 2009; 30(5): 876 - 884.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. d'Assignies, A. Couvelard, S. Bahrami, M.-P. Vullierme, P. Hammel, O. Hentic, A. Sauvanet, P. Bedossa, P. Ruszniewski, and V. Vilgrain
Pancreatic Endocrine Tumors: Tumor Blood Flow Assessed with Perfusion CT Reflects Angiogenesis and Correlates with Prognostic Factors
Radiology, February 1, 2009; 250(2): 407 - 416.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. Goh, S. Halligan, A. Gharpuray, D. Wellsted, J. Sundin, and C. I. Bartram
Quantitative Assessment of Colorectal Cancer Tumor Vascular Parameters by Using Perfusion CT: Influence of Tumor Region of Interest
Radiology, June 1, 2008; 247(3): 726 - 732.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P.C. Sanelli, G. Nicola, R. Johnson, A.J. Tsiouris, I. Ougorets, C. Knight, B. Frommer, S. Veronelli, and R.D. Zimmerman
Effect of Training and Experience on Qualitative and Quantitative CT Perfusion Data
AJNR Am. J. Neuroradiol., March 1, 2007; 28(3): 428 - 432.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Roentgen Ray Society.