AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brennan, P. C.
Right arrow Articles by Manning, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brennan, P. C.
Right arrow Articles by Manning, D. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.05.2048
AJR 2007; 188:W177-W180
© American Roentgen Ray Society


Original Research

Ambient Lighting: Effect of Illumination on Soft-Copy Viewing of Radiographs of the Wrist

Patrick C. Brennan1, Mark McEntee1, Michael Evanoff2, Peter Phillips3, William T. O'Connor4 and David J. Manning3

1 School of Medicine and Medical Sciences, University College Dublin, Health Science Bldg., Belfield, Dublin 4, Ireland.
2 American Board of Radiology, Tucson, AZ 85711.
3 School of Medical Imaging Sciences, St. Martin's College, Lancaster, UK LA1 3JD.
4 Applied Neurotherapeutics Research Group, Conway Institute, University College Dublin, Dublin 4, Ireland.

OBJECTIVE. The aim of the work was to establish optimum ambient light conditions for viewing radiologic images of the wrist on liquid crystal display monitors.

MATERIALS AND METHODS. Five ambient light levels were investigated: 480, 100, 40, 25, and 7 lux. Seventy-nine experienced radiologists were asked to examine 30 posteroanterior wrist images and decide whether a fracture was present. All images were displayed on liquid crystal display monitors. Receiver operating characteristic analysis was performed, and the numbers of false-positive and false-negative findings were recorded.

RESULTS. For all the radiologists, greater area under the receiver operating characteristic curve and lower numbers of false-positive and false-negative findings were recorded at 40 and 25 lux compared with 480 and 100 lux. At 7 lux, the results were generally similar to those at 480 and 100 lux. The experience and knowledge of radiologists specializing in imaging of musculoskeletal trauma appeared to compensate in part for inappropriate lighting levels.

CONCLUSION. Typical office lighting and current recommendations on ambient lighting can reduce diagnostic efficacy compared with lower levels of ambient lighting. If, however, no light other than that of the monitor is used, results are similar to those with excessive levels of lighting. Careful control of ambient lighting is therefore required to ensure that diagnostic accuracy is maximized, particularly for clinicians not expert in interpreting posteroanterior wrist images.

Keywords: lighting • PACS • wrist • X-ray technology