AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thompson, W. M.
Right arrow Articles by Paulson, E. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thompson, W. M.
Right arrow Articles by Paulson, E. K.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.06.0817
AJR 2007; 188:W233-W238
© American Roentgen Ray Society


Original Research

Accuracy of Abdominal Radiography in Acute Small-Bowel Obstruction: Does Reviewer Experience Matter?

William M. Thompson1, Ramsey K. Kilani, Benjamin B. Smith, John Thomas, Tracy A. Jaffe, David M. Delong and Erik K. Paulson

1 All authors: Department of Radiology, Duke University Medical Center, Box 3808, Durham, NC 27710.

OBJECTIVE. The purposes of this study were to determine the accuracy of abdominal radiography in the detection of acute small-bowel obstruction (SBO), to assess the role of reviewer experience, and to evaluate individual radiographic signs of SBO.

MATERIALS AND METHODS. A retrospective study was performed in which the subjects were 90 patients with suspected SBO who underwent CT and abdominal radiography within 48 hours of each other. The patients were enrolled from June 1, 2003, to February 2004. Twentynine of the patients had proven SBO. Hard-copy radiographs were reviewed by three groups of radiologists: senior staff, junior staff, and second-year radiology residents. Each reviewer evaluated the quality of the radiographs, patient position for acquisition of the radiographs, and whether SBO was present. The reviewers rated their confidence on a five-point scale and recorded the presence or absence of specific radiographic signs of SBO. Chi-square tests were used to compare the three groups. A statistically significant finding was considered p < 0.05. Receiver operating characteristic (ROC) curves were fit with a 10-point confidence scale.

RESULTS. The sensitivity for SBO among the six reviewers ranged from 59% to 93%. The senior staff members were significantly more accurate. The mean sensitivity, specificity, and accuracy for all six reviewers were 82%, 83%, and 83%, respectively. Three radiographic signs were highly significant (p < 0.001): two or more air-fluid levels, air-fluid levels wider than 2.5 cm, and air-fluid levels differing more than 5 mm from one another in the same loop of small bowel. ROC analysis showed that senior staff is significantly more accurate than the other groups in the detection of acute SBO.

CONCLUSION. Our results confirmed that abdominal radiographs are accurate in the detection of acute SBO, that more-experienced radiologists are more accurate than less-experienced reviewers in the evaluation of abdominal radiographs, and that three types of air-fluid levels are highly predictive of the presence of SBO.

Keywords: abdominal imaging • radiography • small bowel


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
ImagingHome page
E M Anderson
Imaging of acute small bowel obstruction
Imaging, December 1, 2006; 18(4): 198 - 207.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Roentgen Ray Society.