AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rubaltelli, L.
Right arrow Articles by Stramare, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rubaltelli, L.
Right arrow Articles by Stramare, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.06.0562
AJR 2007; 188:977-983
© American Roentgen Ray Society


Original Research

Automated Quantitative Evaluation of Lymph Node Perfusion on Contrast-Enhanced Sonography

Leopoldo Rubaltelli1, Simone Corradin1, Alberto Dorigo1, Alberto Tregnaghi1, Fausto Adami2, Carlo Riccardo Rossi3 and Roberto Stramare1

1 Department of Medical Diagnostic Sciences and Special Therapies, University of Padua-Italy, via Giustiniani 2, Padua 35100, Italy.
2 Department of Clinical and Experimental Medicine, University of Padua-Italy, Padua, Italy.
3 Department of Oncological and Surgical Sciences, University of Padua-Italy, Padua, Italy.

OBJECTIVE. The aim of this study was to assess the performance of experimental software (Qontraxt) intended to provide automated quantification of sonographic signal intensity, which is related to the contrast enhancement of lymph node tissue, to differentiate benign from malignant lymph nodes.

SUBJECTS AND METHODS. In 31 patients (age range, 24-86 years; mean age ± SD, 53.6 ± 14.4 years) a single lymph node per patient was evaluated on sonography after the administration of sulfur hexafluoride-filled microbubbles. The stored sonographic images were analyzed and processed into chromatic maps that had numeric values related to the amount of contrast. The lymph node regions in which the increase of signal intensity values with respect to baseline were highest (maximum signal intensity value [SImax]) and lowest (minimum signal intensity value [SImin]) were identified, and the corresponding numeric data were stored. Statistical analyses were performed by means of the Student's t test; a p value of less than 0.05 was considered to be statistically significant.

RESULTS. Histopathologic analysis revealed metastatic lesions in 12 of the 31 lymph nodes; the remaining 19 were benign (16 reactive lymph nodes, two cases of granulomatous lymphadenitis, and one case of tubercular lymphadenitis). Values obtained from the SImax regions showed no consistent difference between benign and malignant lymph nodes; on the other hand, values from the SImin regions comparing baseline and maximal contrast-enhanced values were significantly different in the two groups (p < 0.001). Confidence for characterization of malignancy was significant using the difference between values from SImax and SImin regions, with the higher disgnostic value from 24 to 31 inclusive: sensitivity, 92% (11/12); specificity, 89% (17/19); positive predictive value, 85% (11/13); and accuracy, 90% (28/31).

CONCLUSION. The software being tested proved to be useful in differentiating benign from metastatic lymph nodes on the basis of the quantitative data it provided.

Keywords: automated perfusion measurements • color Doppler sonography • contrast media • lymph nodes • oncologic imaging • software • sonography


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Roentgen Ray Society.