AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goodman, L. R.
Right arrow Articles by Yankelevitz, D. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goodman, L. R.
Right arrow Articles by Yankelevitz, D. F.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.07.2182
AJR 2007; 189:409-412
© American Roentgen Ray Society


Original Research

CT Venography for Deep Venous Thrombosis: Continuous Images Versus Reformatted Discontinuous Images Using PIOPED II Data

Lawrence R. Goodman1, Paul D. Stein2,3, Afzal Beemath2, H. Dirk Sostman4,5, Thomas W. Wakefield6, Pamela K. Woodard7 and David F. Yankelevitz8

1 Department of Radiology, Medical College of Wisconsin, 9200 W Wisconsin Ave., Milwaukee, WI 53226-3596.
2 Department of Research, St. Joseph Mercy Hospital-Oakland, Pontiac, MI.
3 Department of Medicine, Wayne State University, Detroit, MI.
4 Office of the Vice President, Weill Cornell Medical College, New York, NY.
5 Office of the Vice President, Methodist Hospital, Houston, TX.
6 Department of Surgery, University of Michigan, Ann Arbor, MI.
7 Department of Radiology, Washington University, St. Louis, MO.
8 Department of Radiology, Weill Cornell Medical College, New York, NY.

OBJECTIVE. This study was designed to determine whether discontinuous CT of the lower extremities for the detection of deep venous thrombosis (DVT) yields results similar to those of complete helical imaging using cases from the Prospective Investigation of Pulmonary Embolism Diagnosis II (PIOPED II).

MATERIALS AND METHODS. In PIOPED II, CT venography followed CT angiography (CTA) to detect pulmonary embolus, using 7.5-mm continuous helical imaging from the iliac crest to the tibial plateau. DVT was detected in 105 of 737 patients (14.2%). We randomly chose 54 positive cases and 96 negative cases for our study. The continuous helical images were reformatted as 7.5-mm images and two of every three images were deleted. These images (7.5 mm; skip = 15 mm) were then sent—without identifying information—to the original reviewers. From 1 to 3.5 years had elapsed since the original interpretations. The results of the new interpretations were compared with the original CT venography consensus interpretations of PIOPED II.

RESULTS. There was agreement for the presence of DVT in at least one leg (same leg) or for the absence of DVT in both legs in 133 of the 150 study patients (89%). The kappa statistic showed substantial agreement between the consensus interpretations and the test interpretations ({kappa} = 0.75; 95% CI = 0.64-0.86) per patient.

CONCLUSION. There was good—but not perfect—agreement between continuous helical and discontinuous axial imaging for the detection of DVT. Given the vagaries of interobserver and intraobserver variation, there appears to be little difference between the two approaches. Adopting discontinuous imaging and other dose-reduction strategies can reduce pelvic radiation by more than 75%.

Keywords: CT venography • deep venous thrombosis • emergency radiology • PIOPED II • pulmonary embolism • thromboembolic disease • venous thromboembolism


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
L. R. Goodman, P. D. Stein, F. Matta, H. D. Sostman, T. W. Wakefield, P. K. Woodard, R. Hull, D. F. Yankelevitz, and A. Beemath
CT Venography and Compression Sonography Are Diagnostically Equivalent: Data from PIOPED II
Am. J. Roentgenol., November 1, 2007; 189(5): 1071 - 1076.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Roentgen Ray Society.