AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME Credit
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Georgian-Smith, D.
Right arrow Articles by Kopans, D. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Georgian-Smith, D.
Right arrow Articles by Kopans, D. B.
DOI:10.2214/AJR.07.2393
AJR 2007; 189:1135-1141
© American Roentgen Ray Society


Original Research

Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography

Dianne Georgian-Smith1, Richard H. Moore2, Elkan Halpern3, Eren D. Yeh1, Elizabeth A. Rafferty2, Helen Anne D'Alessandro2, Mary Staffa2, Deborah A. Hall2, Kathleen A. McCarthy2 and Daniel B. Kopans2

1 Department of Radiology, Breast Imaging, Brigham and Women's Hospital, 75 Francis St., Boston, MA 02115.
2 AVON Breast Center, Boston, MA.
3 Department of Radiology, Institute of Technology Assessment, Massachusetts General Hospital, Boston, MA.

OBJECTIVE. The purpose of this study was to compare a human second reader with computer-aided detection (CAD) for the reduction of false-negative cases by a primary radiologist. We retrospectively reviewed our clinical practice.

MATERIALS AND METHODS. We found that 6,381 consecutive screening mammograms were interpreted by a primary reader. This radiologist then reinterpreted the studies using CAD ("CAD reader"). A second human reader who was blinded to the CAD results but knowledgeable of the primary reader's findings reviewed the studies, looking for abnormalities not seen by the first reader.

RESULTS. Two cancers were called back by the second human reader that were not called back by the CAD reader; however, the CAD system had marked the findings, but they were dismissed by the primary reader. Because of the small numbers, the difference between the CAD and second human reader was not statistically significant. The CAD and human second readers increased the recall rates 6.4% and 7.2% (p = 0.70), respectively, and the biopsy rates 10% and 14.7%. The positive predictive value was 0% (0/3) for the CAD reader and was 40% (2/5) for the human second reader. The relative increases in the cancer detection rate compared with the primary reader's detection rate were 0% for the CAD reader and 15.4% (2/13) for the human second reader (p = 0.50).

CONCLUSION. A human second reader or the use of a CAD system can increase the cancer detection rate, but we found no statistical difference between the two because of the small sample size. A possible benefit from a human second reader is that CAD systems can only point to possible abnormalities, whereas a human must determine the significance of the finding. Having two humans review a study may increase detection rates due to interpreter—hence, perceptual—variability and not just increased detection.

Keywords: breast cancer • computer-aided detection • mammography • mammography recall rates • screening mammography




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
R. F. Brem
Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography: The Importance of the Question and the Critical Numbers Game
Am. J. Roentgenol., November 1, 2007; 189(5): 1142 - 1144.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Roentgen Ray Society.