AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Choi, H.
Right arrow Articles by Ma, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Choi, H.
Right arrow Articles by Ma, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.07.2998
AJR 2008; 190:1055-1059
© American Roentgen Ray Society


Original Research

Use of Perfluorocarbon Compound in the Endorectal Coil to Improve MR Spectroscopy of the Prostate

Haesun Choi1 and Jingfei Ma2

1 Department of Diagnostic Radiology, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Box Unit 368, Houston, TX 77030.
2 Department of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX.

OBJECTIVE. The purpose of this study was to evaluate the utility of perfluorocarbon (PFC) compound compared with air in the endorectal coil in improving the quality of conventional MR spectroscopy of the prostate.

SUBJECTS AND METHODS. A total of 62 consecutively registered patients were selected. MR spectroscopy of the prostate was performed with PFC in the endorectal coil for 34 of the patients and with air for 28. In the cases of 13 of the 28 patients, MR spectroscopy was repeated with a PFC-filled endorectal coil. The spectral line widths and the spectral separations from MR spectroscopy with an air-filled endorectal coil were compared with those obtained with a PFC-filled coil.

RESULTS. In all 62 patients, the mean line width values were reduced, from 13.3 ± 3.0 Hz with air to 7.3 ± 2.0 Hz with PFC (p = 0.0001, Student's t test). In 13 patients who underwent MR spectroscopy with air followed by MR spectroscopy with PFC, the mean line width values were reduced, from 14.8 ± 3.4 Hz with air to 7.0 ± 1.5 Hz with PFC (p = 0.0001, Student's t test). In 72 voxels analyzed for spectral separation, clear separations between the choline, polyamine, and creatine peaks were found in 57 voxels with PFC and four with air. Better splitting of the citrate peaks was found in 35 voxels with PFC and one with air.

CONCLUSION. The use of PFC compound in the endorectal coil is a safe and cost-effective way to consistently generate high-quality prostate MR spectroscopic results and to substantially improve quantitation of prostatic metabolites. These improvements should increase the diagnostic value of MR spectroscopy in the care of patients with prostate cancer.

Keywords: carcinoma • MR spectroscopy • perfluorocarbon • prostate


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Roentgen Ray Society.