AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Imamura, K.
Right arrow Articles by Uesugi, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Imamura, K.
Right arrow Articles by Uesugi, K.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.07.2610
AJR 2008; 190:W234-W236
© American Roentgen Ray Society


Technical Innovation

Microcalcifications of Breast Tissue: Appearance on Synchrotron Radiation Imaging with 6-µm Resolution

Keiko Imamura1, Norishige Ehara1, Yoichi Inada2, Yoshihide Kanemaki1, Joji Okamoto3, Ichiro Maeda4, Keiko Miyamoto3, Haruki Ogata3, Hisanori Kawamoto3, Yasuo Nakajima1, Mamoru Fukuda3, Keiji Umetani5 and Kentarou Uesugi5

1 Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ward, Kawasaki, Kanagawa 216-8511, Japan.
2 Department of Physics, St. Marianna University School of Medicine, Kawasaki, Japan.
3 Department of Breast Surgery, St. Marianna University School of Medicine, Kawasaki, Japan.
4 Department of Pathology, St. Marianna University School of Medicine, Kawasaki, Japan.
5 Japan Synchrotron Radiation Research Institute, Kouto, Hyogo 679-5198, Japan.

OBJECTIVE. The purpose of this study was to use synchrotron radiation imaging with 6-µm resolution to evaluate amorphous and pleomorphic breast tissue microcalcifications.

CONCLUSION. Synchrotron radiation imaging depicted microcalcifications as small as 24 µm. Imaging with this technique revealed that most amorphous and pleomorphic calcifications on conventional mammograms are clusters of fine specks and that in addition to the shape or density of a speck, the distribution density of clustered specks is a factor determining the apparent shape.

Keywords: breast imaging • mammogram • microcalcification • morphology • synchrotron radiation imaging


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Roentgen Ray Society.