AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow WIO
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Bowles, E. J. A.
Right arrow Articles by Elmore, J. G.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowles, E. J. A.
Right arrow Articles by Elmore, J. G.
DOI:10.2214/AJR.07.3041
AJR 2008; 190:1200-1208
© American Roentgen Ray Society


Original Research

Accuracy of Short-Interval Follow-Up Mammograms by Patient and Radiologist Characteristics

Erin J. Aiello Bowles1, Diana L. Miglioretti1, Edward A. Sickles2, Linn Abraham1, Patricia A. Carney3, Bonnie C. Yankaskas4 and Joann G. Elmore5

1 Group Health Center for Health Studies, Group Health Cooperative, 1730 Minor Ave., Ste. 1600, Seattle, WA 98101.
2 Department of Radiology, University of California, San Francisco, San Francisco, CA.
3 Department of Family Medicine, Oregon Health Sciences University, Portland, OR.
4 Department of Radiology, University of North Carolina, Chapel Hill, NC.
5 Department of Internal Medicine, University of Washington School of Medicine, Seattle, WA.

OBJECTIVE. The purpose of our study was to examine the accuracy of short-interval follow-up mammograms and evaluate patient and radiologist characteristics associated with accuracy.

MATERIALS AND METHODS. We evaluated 45,007 initial short-interval follow-up mammograms from the Breast Cancer Surveillance Consortium interpreted 3–9 months after a probably benign assessment on a screening or diagnostic examination between 1994 and 2004. We linked these mammograms with patient characteristics and breast cancer diagnoses within 12 months. A subset of short-interval follow-up examinations (n = 13,907) was merged with radiologist characteristics collected from survey data from 130 interpreting radiologists. Using logistic regression, we fit generalized estimating equations to model sensitivity and specificity of short-interval follow-up mammograms by patient and radiologist characteristics.

RESULTS. For every 1,000 women, 8.0 women (0.8%) were diagnosed with breast cancer within 6 months and 11.3 (1.1%) within 12 months. Sensitivity was 83.3% (95% CI, 79.4–87.3%) for cancers diagnosed within 6 months and 60.5% (56.2–64.7%) for those diagnosed within 12 months. Specificity was 97.2% (96.9–97.6%) at 6 months and 97.3% (96.9–97.6%) at 12 months. Sensitivity at 12 months increased among women with unilateral short-interval follow-up mammograms (odds ratio, 1.56 [95% CI, 1.06–2.29]) and when the interpreting radiologist spent more than 10 hours a week in breast imaging (odds ratio, 3.25 [1.00–10.52]).

CONCLUSION. Initial short-interval follow-up mammography examinations had a lower sensitivity for detecting breast cancer within 12 months than other diagnostic mammograms (61% for short-interval follow-up vs 80% for diagnostic mammograms reported in the literature). However, sensitivity within the 6-month interval that is usually recommended for subsequent follow-up was 83%. Accuracy of short-interval follow-up mammograms was influenced by few patient and radiologist characteristics.

Keywords: breast cancer • diagnostic mammography • sensitivity • short-interval follow-up mammography • specificity







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS