AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muhogora, W. E.
Right arrow Articles by Shandorf, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muhogora, W. E.
Right arrow Articles by Shandorf, C.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.07.3039
AJR 2008; 190:1453-1461
© American Roentgen Ray Society


Original Research

Patient Doses in Radiographic Examinations in 12 Countries in Asia, Africa, and Eastern Europe: Initial Results from IAEA Projects

Wilbroad E. Muhogora1, Nada A. Ahmed2, Aziz Almosabihi3, Jamila S. Alsuwaidi4, Adnan Beganovic5, Olivera Ciraj-Bjelac6, Francois K. Kabuya7, Anchali Krisanachinda8, Milomir Milakovic9, Godfrey Mukwada10, Marie J. Ramanandraibe11, Madan M. Rehani12, Jalil Rouzitalab13 and Cyril Shandorf14

1 Tanzania Atomic Energy Commission, Arusha, Tanzania.
2 Sudan Atomic Energy Commission, Khartoum, Sudan.
3 King Abdul Aziz City for Science and Technology, Riyadh, Saudi Arabia.
4 Dubai Hospital, Dubai, United Arab Emirates.
5 University of Sarajevo, Sarajevo, Bosnia and Herzegovina.
6 Vinca Institute of Nuclear Sciences, Belgrade, Serbia.
7 Centre Régional d'Études Nucléaires de Kinshasa (CREN-K), Kinshasa, Democratic Republic of the Congo.
8 Chulalongkorn Hospital, Bangkok, Thailand.
9 Clinical Centre Banja Luka, Banja Luka, Bosnia and Herzegovina.
10 Radiotherapy and Nuclear Medicine Department, Parirenyatwa Group of Hospitals, Harare, Zimbabwe.
11 Institut National des Sciences et Techniques Nucléaires, Antananarivo, Madagascar.
12 International Atomic Energy Agency, Wagramer Strasse 5, A-1400, Vienna, Austria.
13 Atomic Energy Organization of Iran, Tehran, Iran.
14 Ghana Atomic Energy Commission, Accra, Ghana.

OBJECTIVE. The purpose of this study was to survey image quality and the entrance surface air kerma for patients in radiographic examinations and to perform comparisons with diagnostic reference levels.

SUBJECTS AND METHODS. In this multinational prospective study, image quality and patient radiation doses were surveyed in 12 countries in Africa, Asia, and Eastern Europe, covering 45 hospitals. The rate of unsatisfactory images and image quality grade were noted, and causes for poor image quality were investigated. The entrance surface doses for adult patients were determined in terms of the entrance surface air kerma on the basis of X-ray tube output measurements and X-ray exposure parameters. Comparison of dose levels with diagnostic reference levels was performed.

RESULTS. The fraction of images rated as poor was as high as 53%. The image quality improved up to 16 percentage points in Africa, 13 in Asia, and 22 in Eastern Europe after implementation of a quality control (QC) program. Patient doses varied by a factor of up to 88, although the majority of doses were below diagnostic reference levels. The mean entrance surface air kerma values in mGy were 0.33 (chest, posteroanterior), 4.07 (lumbar spine, anteroposterior), 8.53 (lumbar spine, lateral), 3.64 (abdomen, anteroposterior), 3.68 (pelvis, anteroposterior), and 2.41 (skull, anteroposterior). Patient doses were found to be similar to doses in developed countries and patient dose reductions ranging from 1.4% to 85% were achieved.

CONCLUSION. Poor image quality constitutes a major source of unnecessary radiation to patients in developing countries. Comparison with other surveys indicates that patient dose levels in these countries are not higher than those in developed countries.

Keywords: patient doses • quality assurance • radiation protection • radiation safety • radiography


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
M. M. Rehani
THE IAEA'S ACTIVITIES IN RADIOLOGICAL PROTECTION IN DIGITAL IMAGING
Radiat Prot Dosimetry, June 3, 2008; (2008) ncn155v2.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Roentgen Ray Society.