OBJECTIVE. The objective of our study was to assess the effects of compressing source thin-section abdominal CT images on final transverse average-intensity-projection (AIP) images.
MATERIALS AND METHODS. At reversible, 4:1, 6:1, 8:1, 10:1, and 15:1 Joint Photographic Experts Group (JPEG) 2000 compressions, we compared the artifacts in 20 matching compressed thin sections (0.67 mm), compressed thick sections (5 mm), and AIP images (5 mm) reformatted from the compressed thin sections. The artifacts were quantitatively measured with peak signal-to-noise ratio (PSNR) and a perceptual quality metric (High Dynamic Range Visual Difference Predictor [HDR-VDP]). By comparing the compressed and original images, three radiologists independently graded the artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). Friedman tests and exact tests for paired proportions were used.
RESULTS. At irreversible compressions, the artifacts tended to increase in the order of AIP, thick-section, and thin-section images in terms of PSNR (p < 0.0001), HDR-VDP (p < 0.0001), and the readers' grading (p < 0.01 at 6:1 or higher compressions). At 6:1 and 8:1, distinguishable pairs (grades 1-3) tended to increase in the order of AIP, thick-section, and thin-section images. Visually lossless threshold for the compression varied between images but decreased in the order of AIP, thick-section, and thin-section images (p < 0.0001).
CONCLUSION. Compression artifacts in thin sections are significantly attenuated in AIP images. On the premise that thin sections are typically reviewed using an AIP technique, it is justifiable to compress them to a compression level currently accepted for thick sections.
Keywords: abdominal imaging artifacts average intensity projection CT data compression human visual system image quality metric JPEG 2000
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
S. J. Kim, H.-H. Kim, Y. H. Kim, S. H. Hwang, H. S. Lee, D. J. Park, S. Y. Kim, and K. H. Lee Peritoneal Metastasis: Detection with 16- or 64-Detector Row CT in Patients Undergoing Surgery for Gastric Cancer Radiology, November 1, 2009; 253(2): 407 - 415. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-M. Joo, K. H. Lee, Y. H. Kim, S. Y. Kim, K. Kim, K. J. Kim, and B. Kim Detection of the Normal Appendix with Low-Dose Unenhanced CT: Use of the Sliding Slab Averaging Technique Radiology, June 1, 2009; 251(3): 780 - 787. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |