AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Compression Artifacts
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, B.
Right arrow Articles by Kim, Y. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, B.
Right arrow Articles by Kim, Y. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.07.3405
AJR 2008; 190:W342-W350
© American Roentgen Ray Society


Original Research

Artifacts in Slab Average-Intensity-Projection Images Reformatted from JPEG 2000 Compressed Thin-Section Abdominal CT Data Sets

Bohyoung Kim1, Kyoung Ho Lee1, Kil Joong Kim1, Rafal Mantiuk2, Hye-ri Kim1 and Young Hoon Kim1

1 Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea; and Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggido, 463-707, Korea.
2 Max-Planck-Institut für Informatik, Department 4, Computer Graphics Bldg. 46.1, Rm. 227, Stuhlsatzenhausweg 85, 66123 Saarbrücken, Germany.

OBJECTIVE. The objective of our study was to assess the effects of compressing source thin-section abdominal CT images on final transverse average-intensity-projection (AIP) images.

MATERIALS AND METHODS. At reversible, 4:1, 6:1, 8:1, 10:1, and 15:1 Joint Photographic Experts Group (JPEG) 2000 compressions, we compared the artifacts in 20 matching compressed thin sections (0.67 mm), compressed thick sections (5 mm), and AIP images (5 mm) reformatted from the compressed thin sections. The artifacts were quantitatively measured with peak signal-to-noise ratio (PSNR) and a perceptual quality metric (High Dynamic Range Visual Difference Predictor [HDR-VDP]). By comparing the compressed and original images, three radiologists independently graded the artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). Friedman tests and exact tests for paired proportions were used.

RESULTS. At irreversible compressions, the artifacts tended to increase in the order of AIP, thick-section, and thin-section images in terms of PSNR (p < 0.0001), HDR-VDP (p < 0.0001), and the readers' grading (p < 0.01 at 6:1 or higher compressions). At 6:1 and 8:1, distinguishable pairs (grades 1-3) tended to increase in the order of AIP, thick-section, and thin-section images. Visually lossless threshold for the compression varied between images but decreased in the order of AIP, thick-section, and thin-section images (p < 0.0001).

CONCLUSION. Compression artifacts in thin sections are significantly attenuated in AIP images. On the premise that thin sections are typically reviewed using an AIP technique, it is justifiable to compress them to a compression level currently accepted for thick sections.

Keywords: abdominal imaging • artifacts • average intensity projection • CT • data compression • human visual system • image quality metric • JPEG 2000


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
S. J. Kim, H.-H. Kim, Y. H. Kim, S. H. Hwang, H. S. Lee, D. J. Park, S. Y. Kim, and K. H. Lee
Peritoneal Metastasis: Detection with 16- or 64-Detector Row CT in Patients Undergoing Surgery for Gastric Cancer
Radiology, November 1, 2009; 253(2): 407 - 415.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S.-M. Joo, K. H. Lee, Y. H. Kim, S. Y. Kim, K. Kim, K. J. Kim, and B. Kim
Detection of the Normal Appendix with Low-Dose Unenhanced CT: Use of the Sliding Slab Averaging Technique
Radiology, June 1, 2009; 251(3): 780 - 787.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Roentgen Ray Society.