AJR Customized AJR reprints in quantities as low as 100!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bajpai, V.
Right arrow Articles by Kang, H. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bajpai, V.
Right arrow Articles by Kang, H. S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.07.3350
AJR 2008; 191:W38-W43
© American Roentgen Ray Society


Original Research

Differences in Compression Artifacts on Thin- and Thick-Section Lung CT Images

Vasundhara Bajpai1, Kyoung Ho Lee1, Bohyoung Kim1, Kil Joong Kim1, Tae Jung Kim1, Young Hoon Kim1 and Heung Sik Kang1

1 All authors: Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-707, Korea; and Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research, Seoul, Korea.

OBJECTIVE. The purpose of our study was to show the difference of Joint Photographic Experts Group (JPEG) 2000 compression artifacts in the lung between thin- and thick-section CT images.

MATERIALS AND METHODS. Thirty-five thin-section (1 mm) and 35 corresponding thick-section (5 mm) images were compressed to reversible and irreversible 4:1, 6:1, 8:1, 10:1, and 15:1. In each compressed image, pixels outside the lung were replaced with those from the original image. By comparing the compressed and original images, three radiologists independently rated the compression artifacts using grades of 0 (none, the two images were indistinguishable), 1 (image differences were barely perceptible), 2 (image differences were subtle), or 3 (image differences were significant). At each compression level, thin and thick sections were compared for peak signal-to-noise ratio (PSNR) using paired t tests and for the readers' responses using Wilcoxon's signed rank tests and exact tests for paired proportions.

RESULTS. Thin sections had smaller PSNR (p < 0.0001). Thin sections had higher grades of artifacts than thick sections, showing significant differences at compression levels of 10:1 (mean score, 0.8 vs 0.4, 0.9 vs 0.1, 0.3 vs 0.0; p < 0.009 for the three readers) and 15:1 (1.9 vs 1.0, 1.9 vs 1.1, 1.5 vs 0.6; p < 0.0001). The percentages of distinguishable pairs (grades 1–3) were greater for thin sections than for thick sections, showing a statistically significant difference at 10:1 for two readers (31% vs 3% and 74% vs 37%; p < 0.006).

CONCLUSION. The lung shows more compression artifacts on thin sections than on thick sections. Section thickness should be taken into consideration when adjusting the compression level for lung CT images.

Keywords: artifacts • CT • data compression • lung