AJR Get Involved! Great Benefits! Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Youn, S. W.
Right arrow Articles by Bae, H.-J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Youn, S. W.
Right arrow Articles by Bae, H.-J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.07.2519
AJR 2008; 191:W120-W126
© American Roentgen Ray Society


Original Research

Perfusion CT of the Brain Using 40-mm-Wide Detector and Toggling Table Technique for Initial Imaging of Acute Stroke

Sung Won Youn1, Jae Hyoung Kim1, Young-Cheol Weon1, Sung Hyun Kim1, Moon-Ku Han2 and Hee-Joon Bae2

1 Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam-si, 463-707, Korea.
2 Department of Neurology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam-si, Korea.

OBJECTIVE. Limited coverage of the brain in the z-axis has been a drawback of perfusion CT. The purpose of this study was to evaluate the usefulness of perfusion CT with extended coverage in the z-axis for the assessment of acute stroke in an emergent clinical setting.

MATERIALS AND METHODS. Fifty-eight patients who underwent 80-mm-coverage perfusion CT within 24 hours after stroke onset were included. Perfusion CT was performed using a 64-MDCT unit equipped with 40-mm-wide detector and the toggling table technique. Lesion detection by perfusion CT was analyzed using follow-up diffusion-weighted imaging and MR angiography as the reference standards. More conventional 20-mm-coverage perfusion CT was simulated by extracting data obtained at the basal ganglia level for comparison with 80-mm-coverage perfusion CT.

RESULTS. Fifty-one patients had acute infarctions and seven patients did not. For 80-mm-coverage perfusion CT, perfusion abnormality was detected in 42 of 51 patients (sensitivity, 82.4%; and specificity, 85.7%). When patients with small artery disease (small acute infarctions in the basal ganglia, thalamus, corona radiata, and pons) were excluded, sensitivity increased to 92.3%. As compared with 80-mm-coverage perfusion CT, 20-mm-coverage perfusion CT missed nine acute infarctions located above or below the level of the basal ganglia (p = 0.0039).

CONCLUSION. Perfusion CT with 80-mm-coverage was found to be useful as an initial imaging method in acute ischemic stroke, although it had low sensitivity for detecting small acute infarctions. In particular, this technique provided higher lesion detection than 20-mm-coverage perfusion CT.

Keywords: cerebral ischemia • CT • perfusion


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Roentgen Ray Society.