AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kubo, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kubo, T.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR/07.2630
AJR 2008; 191:W167-W174
© American Roentgen Ray Society


Original Research

Use of 3D Adaptive Raw-Data Filter in CT of the Lung: Effect on Radiation Dose Reduction

Takeshi Kubo1,2, Yoshiharu Ohno3, Shiva Gautam1, Pei-Jan P. Lin1, Hans-Ulrich Kauczor4,5, Hiroto Hatabu6 iLEAD Study Group

1 Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA.
2 Present address: Department of Diagnostic Imaging and Nuclear Medicine, Gradute School of Medicine, Kyoto University, Kyoto, Japan.
3 Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.
4 Department of Radiology, German Cancer Research Center, Heidelberg, Germany.
5 Present address: Department of Diagnostic and International Radiology, University Clinic Heidelberg, Heidelberg, Germany.
6 Department of Radiology, Brigham and Women's Hospital, 75 Francis St., Boston, MA 02115.

OBJECTIVE. The purpose of this study was to determine the effectiveness of a 3D adaptive raw-data filter in improving image quality and the role of the filter in radiation dose reduction in lung CT.

MATERIALS AND METHODS. Fifty-eight chest CT examinations were performed with a 16-MDCT scanner. Two acquisitions were performed with different tube current–exposure time settings (50 and 150 mAs, 120 kVp). Four series of lung images were prepared from two sets of raw data with and without application of a 3D adaptive filter (50 mAs, 50 mAs with filter, 150 mAs, 150 mAs with filter). Three blinded readers using a 5-point scale from 1 (nondiagnostic) to 5 (excellent) independently evaluated image quality in five lobes and the lingula. A set of images was considered acceptable when scores in all six regions were 3 (acceptable) or higher. The SD of attenuation was calculated in 24 regions of interest.

RESULTS. The overall mean image quality scores were 3.09, 3.53, 4.02, and 4.38 for the 50 mAs, 50 mAs with filter, 150 mAs, and 150 mAs with filter sets, respectively. Scores were significantly better with filter application (p < 0.001). A significant decrease in SD of attenuation was observed with filter application (p < 0.001). Among the respective series of images, 18, 52, 50, and 58 sets were judged acceptable with no significant difference in acceptability between images obtained at 50 mAs with a filter and at 150 mAs (p = 0.72). With filter application, the acceptability of 50-mAs images became comparable with that of 150-mAs images, making dose reduction to 50 mAs practical.

CONCLUSION. Use of a 3D adaptive raw-data filter improved the quality of lung images, making dose reduction to 50 mAs attainable with use of the filter.

Keywords: artifacts • chest CT • imaging filter • radiation dose