AJR Custom publishing of AJR articles and ARRS Cat. Course
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Uitert, R. L.
Right arrow Articles by Pickhardt, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Uitert, R. L.
Right arrow Articles by Pickhardt, P. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.07.3591
AJR 2008; 191:1503-1508
© American Roentgen Ray Society


Original Research

Temporal and Multiinstitutional Quality Assessment of CT Colonography

Robert L. Van Uitert1, Ronald M. Summers1, Jacob M. White1, Keshav K. Deshpande1, J. Richard Choi2,3 and Perry J. Pickhardt4

1 Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bldg. 10, Rm. 1C368X MSC 1182, Bethesda, MD 20892-1182.
2 Department of Radiology, Walter Reed Army Medical Center, Washington, DC.
3 Department of Radiology, Uniformed Services University of the Health Sciences, Bethesda, MD.
4 Department of Radiology, University of Wisconsin Medical School, Madison, WI.

OBJECTIVE. The purpose of this study was to investigate the variability of CT colonography (CTC) scan quality obtained within and between institutions by using previously validated automated quality assessment (QA) software that assesses colonic distention and surface area obscured by residual fluid.

MATERIALS AND METHODS. The CTC scans of 120 patients were retrospectively selected, 30 from each of four institutions. The bowel preparation included oral contrast material for fecal and fluid tagging. Patients at one institution (institution 4) drank half the amount of oral contrast material compared with the patients at the other three institutions. Fifteen of the CTC scans were from the beginning of the protocol studied at each institution and 15 scans were from the same protocol acquired approximately 1 year later in the study. We used previously validated QA software to automatically measure the mean distention and residual fluid of each of five colonic segments (ascending, transverse, descending, sigmoid, and rectum). Adequate distention was defined as a colonic diameter of at least 2 cm. Residual fluid was determined by the percentage of colonic surface area covered by fluid. We compared how the quality varied across multiple institutions and over time within the same institution.

RESULTS. No significant difference in the amount of colonic distention among the four institutions was found (p = 0.19). However, the distention in the prone position was significantly greater than the distention in the supine position (p < 0.001). Patients at institution 4 had about half the amount of residual colonic fluid compared with patients at the other three institutions (p < 0.01). The sigmoid and descending colons were the least distended segments, and the transverse and descending colons contained the most fluid on the prone and supine scans, respectively. More recently acquired studies had greater distention and less residual fluid, but the differences were not statistically significant (p = 0.30 and p = 0.96, respectively).

CONCLUSION. Across institutions, a significant difference can exist in bowel preparation quality for CTC. This study reaffirms the need for standardized bowel preparation and quality monitoring of CTC examinations to reduce poor CTC performance.

Keywords: colon • colonography • CT • quality • virtual colonoscopy