AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nguyen, D.
Right arrow Articles by Poletti, P.-A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nguyen, D.
Right arrow Articles by Poletti, P.-A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.07.3702
AJR 2009; 192:3-10
© American Roentgen Ray Society


Original Research

Evaluation of a Single-Pass Continuous Whole-Body 16-MDCT Protocol for Patients with Polytrauma

Duy Nguyen1, Alexandra Platon1, Kathirkamanathan Shanmuganathan2, Stuart E. Mirvis2, Christoph D. Becker1 and Pierre-Alexandre Poletti1

1 Department of Radiology, Geneva University Hospital, 24 rue Micheli-du-Crest, Geneva 1211, Switzerland.
2 Department of Radiology, University of Maryland School of Medicine, Baltimore, MD.

OBJECTIVE. The purpose of this study was to compare a conventional multiregional MDCT protocol with two continuous single-pass whole-body MDCT protocols in imaging of patients with polytrauma.

SUBJECTS AND METHODS. Ninety patients with polytrauma underwent whole-body 16-MDCT with a conventional (n = 30) or one of two single-pass (n = 60) protocols. The conventional protocol included unenhanced scans of the head and cervical spine and contrast-enhanced helical scans (140 mL, 4 mL/s, 300 mg I/mL) of the thorax and abdomen. The single-pass protocols consisted of unenhanced scans of the head followed by one-sweep acquisition from the circle of Willis through the pubic symphysis with a biphasic (150 mL, 6 and 4 mL/s, 300 mg I/mL) or monophasic (110 mL, 4 mL/s, 400 mg I/mL) injection. Acquisition times and interval delays between head, chest, and abdominal scans were recorded. Contrast enhancement was measured in the aortic arch, liver, spleen, and kidney. Diagnostic image quality in the same areas was assessed on a 4-point scale.

RESULTS. Median acquisition times for the single-pass protocols were significantly shorter (-42.5%) than the acquisition time for the conventional protocol. No significant differences were found in mean enhancement values in the aorta, liver, spleen, and kidney for the three protocols. The image quality with both single-pass protocols was better than that with the conventional protocol in assessment of the mediastinum and cervical spine (p < 0.05). There was no significant difference between the single-pass protocols.

CONCLUSION. Use of single-pass continuous whole-body MDCT protocols can significantly decrease examination time for patients with polytrauma and improve image quality compared with a conventional serial scan protocol. Monophasic injection with highly concentrated contrast medium can reduce injection flow rate and should therefore be preferred to a biphasic injection technique.

Keywords: emergency radiology • MDCT • polytrauma


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. M. Hall
Single-Pass Continuous Whole-Body CT for Polytrauma
Am. J. Roentgenol., August 1, 2009; 193(2): 594 - 594.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P.-A. Poletti and S. E. Mirvis
Reply
Am. J. Roentgenol., August 1, 2009; 193(2): 594 - 594.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Roentgen Ray Society.