AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simpfendorfer, C.
Right arrow Articles by Remer, E. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simpfendorfer, C.
Right arrow Articles by Remer, E. M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.1180
AJR 2009; 192:438-443
© American Roentgen Ray Society


Original Research

Angiomyolipoma with Minimal Fat on MDCT: Can Counts of Negative-Attenuation Pixels Aid Diagnosis?

Claus Simpfendorfer1, Brian R. Herts1, Gaspar A. Motta-Ramirez1,2, Daniel S. Lockwood1, Ming Zhou3, Michael Leiber4 and Erick M. Remer1

1 Section of Abdominal Imaging, Imaging Institute, Desk Hb6, Cleveland Clinic, 9500 Euclid Ave., Cleveland, OH 44195.
2 Present address: Radiologia y Imagen, Hospital Central Militar, Mexico City, Mexico.
3 Section of Anatomic Pathology, Cleveland Clinic, Cleveland, OH.
4 Section of Quantitative Health Sciences, Cleveland Clinic, Cleveland, OH.

OBJECTIVE. The purpose of this study was to determine whether counts of pixels with subzero attenuation on CT scans can aid in the diagnosis of renal angiomyolipoma with minimal fat.

MATERIALS AND METHODS. Of 33 angiomyolipomas identified among 719 renal masses resected from 702 patients over 4 years, 15 masses in 15 patients were prospectively diagnosed on the basis of the presence of fat at MDCT. The 18 patients with minimal-fat angiomyolipoma and a matched (age, sex, tumor size) cohort of patients with renal cell carcinoma were included in this study. Three radiologists independently counted the number of pixels with attenuation less than –10, –20, and –30 HU. Receiver operating characteristic analysis of the number of pixels at each cutoff was used to calculate sensitivity, specificity, and positive predictive value with the following criteria: 1, more than 10 pixels less than –20 HU; 2, more than 20 pixels less than –20 HU; 3, more than 5 pixels less than –30 HU.

RESULTS. Using criterion 1, reader A identified six angiomyolipomas; reader B, five; and reader C, two. The combined sensitivity was 24%; specificity, 98%; and positive predictive value, 69%. Using criterion 2, reader A identified three angiomyolipomas; reader B, four; and reader C, two. The combined sensitivity was 17%; specificity, 100%; and positive predictive value, 100%. Using criterion 3, reader A identified four angiomyolipomas; reader B, four; and reader C, two. The combined sensitivity was 18%; specificity, 100%; and positive predictive value, 100%.

CONCLUSION. CT findings of more than 20 pixels with attenuation less than –20 HU and more than 5 pixels with attenuation less than –30 HU have a positive predictive value of 100% in detection of angiomyolipoma, but most angiomyolipomas with minimal fat cannot be reliably identified on the basis of an absolute pixel count.

Keywords: angiomyolipoma • CT • renal neoplasms


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Roentgen Ray Society.