AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tao, C.
Right arrow Articles by Bae, K. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tao, C.
Right arrow Articles by Bae, K. T.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.1307
AJR 2009; 192:624-628
© American Roentgen Ray Society


Original Research

Automated Matching of Pulmonary Nodules: Evaluation in Serial Screening Chest CT

Cheng Tao1, David S. Gierada2, Fang Zhu3, Thomas K. Pilgram2, Jin Hong Wang1 and Kyongtae T. Bae1

1 Department of Radiology, University of Pittsburgh School of Medicine, 3362 Fifth Ave., Pittsburgh, PA 15213.
2 Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO.
3 Department of Radiology, University of Chicago, Chicago, IL.

OBJECTIVE. The purpose of our study was to evaluate the performance of a computer-aided program that performs automated matching of pulmonary nodules imaged in three serial screening chest MDCT studies.

MATERIALS AND METHODS. Forty subjects with pulmonary nodules depicted in three annual (T0, T1, T2) low-dose MDCT screening studies for lung cancer were selected from the National Lung Screening Trial database at a single institution. All CT images were reevaluated by two radiologists in consensus. One hundred forty-three nodules were identified and characterized by type (solid parenchymal, juxtavascular, juxtapleural, and ground-glass opacity) and size (≤ 4 mm, 4–6 mm, 6–8 mm, and > 8 mm). Using an automated program, nodules at T0 were matched to nodules at T1, and the same nodules at T1 were matched to nodules at T2. Associations between nodule matching rate (i.e., number of nodules matched by the program divided by the number of nodules determined to match by radiologists) and nodule type or size were analyzed.

RESULTS. The combined matching rate of the nodules was 92.7% (T0 vs T1, 91.6%; T1 vs T2, 93.7%). By nodule type, the matching rate was 94.6% (parenchymal), 98.4% (juxtavascular), 85.8% (juxtapleural), and 100% (ground-glass opacity), with the rate significantly lower for juxtapleural nodules (p < 0.01). Matching rates were not significantly influenced by nodule size (p = 0.67).

CONCLUSION. The automated matching rate for pulmonary nodules in screening MDCT scans was high (92.7%) and was not affected by the nodule size but was slightly lower with nodules at juxtapleural locations.

Keywords: chest CT • computer-aided diagnosis • lung cancer screening • pulmonary nodules