AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cai, W.
Right arrow Articles by de Moya, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cai, W.
Right arrow Articles by de Moya, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.1339
AJR 2009; 192:830-836
© American Roentgen Ray Society


Original Research

MDCT for Automated Detection and Measurement of Pneumothoraces in Trauma Patients

Wenli Cai1, Malek Tabbara2, Noboru Takata1, Hiroyuki Yoshida1, Gordon J. Harris1, Robert A. Novelline1 and Marc de Moya2

1 Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 25 New Chardon St., 400C, Boston, MA 02114.
2 Division of Trauma, Emergency Surgery, and Surgical Critical Care, Massachusetts General Hospital and Harvard Medical School, Boston, MA.

OBJECTIVE. The size of a pneumothorax is an important index to guide the emergency treatment of trauma patients—chest tube drainage. The purpose of this study was to develop and validate an automated computer-aided volumetry scheme for detection and measurement of pneumothoraces for trauma patients imaged with MDCT.

MATERIALS AND METHODS. Three pigs and 68 trauma patients with at least one diagnosed occult pneumothorax (23 women and 45 men; age range, 14–89 years; mean age, 41 ± 19 years) were selected for the development and validation of our computer-aided volumetry scheme for pneumothorax. Computer-aided volumetry of pneumothorax consisted of five automated steps: extraction of pleural region, detection of pneumothorax candidates, delineation of the detected pneumothorax candidates, reduction of false-positive findings, and report of the volumetric measurement of pneumothoraces.

RESULTS. In the animal study, our computer-aided volumetry scheme yielded a mean value of 24.27 ± 0.64 mL (SD) compared with 25 mL of air volume manually injected in each scan. The correlation coefficients were 0.999 and 0.997 for the in vivo and ex vivo comparison, respectively. In the patient study, the sensitivity of our computer-aided volumetry scheme was 100% with a false-positive rate of 0.15 per case for 32 occult pneumothoraces ≥ 25 mL. The correlation coefficient was 0.999 for manual volumetry comparison. This automated computer-aided volumetry scheme took approximately 3 minutes to finish the detection and measurement per case.

CONCLUSION. The results show that our computer-aided volumetry scheme provides an automated method for accurate and efficient detection and measurement of pneumothoraces in MDCT images of trauma patients.

Keywords: computerized volumetry • emergency radiology • occult pneumothorax • pneumothorax • quantifying pneumothorax


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?