AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME
Right arrow VIDEOS
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fritz, J.
Right arrow Articles by Pereira, P. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fritz, J.
Right arrow Articles by Pereira, P. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.1569
AJR 2009; 192:W161-W167
© American Roentgen Ray Society


Original Research

Freehand Real-Time MRI-Guided Lumbar Spinal Injection Procedures at 1.5 T: Feasibility, Accuracy, and Safety

Jan Fritz1,2, Christoph Thomas2, Stephan Clasen2, Claus D. Claussen2, Jonathan S. Lewin1 and Phillipe L. Pereira2

1 Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 600 N Wolfe St., Baltimore, MD 21287.
2 Department of Diagnostic Radiology, Eberhard-Karls-University Tübingen, Tübingen, Germany.

OBJECTIVE. The purpose of this study was to test the hypothesis that freehand real-time MRI-guided lumbar spinal injection procedures are feasible, accurate, and safe when performed with a clinical open-bore 1.5-T MRI system.

MATERIALS AND METHODS. A retrospective analysis was made of spinal injection procedures performed over an 18-month period. Forty-nine procedures were performed on 37 patients (23 women, 14 men; mean age, 36 years; range, 18–48 years). A rapid FLASH 2D MRI sequence (TR/TE, 9.3/3.5; slice thickness, 5 mm; acquisition time, 1 second) was used for real-time needle placement with freehand technique. Data assessed were type of procedure, qualitative and quantitative image quality, dimensions of needle artifact, rate of successful drug delivery, rate of vascular uptake, time requirements, and occurrence of complications.

RESULTS. Among the 49 procedures, 22 (45%) were nerve root injections, 18 (37%) were facet joint injections, and nine (18%) were epidural injections. The quality of real-time FLASH 2D MR images was sufficient in all cases. Contrast-to-noise ratios were sufficiently high for good delineation of relevant structures. The needle artifact made was remarkably constant with an average overestimation of length of 1.0 ± 0.2 [SD] mm. Drug delivery was successful in all selective nerve root injections and epidural injections. The rate of successful drug delivery was 89% (16 of 18) for facet joint injections. No complete intravascular injections occurred. The mean table time was 36 minutes (range, 23–75 minutes). The mean real-time MRI time was 38 seconds (range, 12–185 seconds). No major complications occurred.

CONCLUSION. We accept the hypothesis that freehand real-time MRI-guided lumbar spinal injection procedures are feasible, accurate, and safe when performed with a clinical open-bore 1.5-T MRI system. We note that real-time MRI guidance has the additional advantage of a complete absence of patient and operator exposure to ionizing radiation.

Keywords: epidural injection • facet joint injection • interventional MRI • nerve root injection • spinal injection


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Roentgen Ray Society.