AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnson, P. T.
Right arrow Articles by Fishman, E. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnson, P. T.
Right arrow Articles by Fishman, E. K.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.1347
AJR 2009; 192:W214-W221
© American Roentgen Ray Society


Review

IV Contrast Infusion for Coronary Artery CT Angiography: Literature Review and Results of a Nationwide Survey

Pamela T. Johnson1, Harpreet K. Pannu1 and Elliot K. Fishman1

1 All authors: The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine, 601 N Caroline St., Baltimore, MD 21287.

OBJECTIVE. The purpose of our study was to review investigations that evaluated contrast infusion using MDCT with submillimeter detector configuration for coronary artery CT angiography (CTA). Published data are supplemented with 2006 survey results from centers practicing 64-MDCT coronary artery angiography.

CONCLUSION. Literature and survey results suggest a consensus for the use of IV contrast volumes < 100 mL, infusion rate of 5 mL/s, and a saline chaser. A range of concentrations can be used to attain target coronary artery attenuation levels.

Keywords: coronary artery • CT • CT angiography • IV contrast material • MDCT • survey