AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Meyer, R. E.
Right arrow Articles by Filippi, C. G.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, R. E.
Right arrow Articles by Filippi, C. G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.2169
AJR 2009; 193:527-532
© American Roentgen Ray Society


Original Research

Discrepancy Rates of On-Call Radiology Residents' Interpretations of CT Angiography Studies of the Neck and Circle of Willis

Russell E. Meyer1, Joshua P. Nickerson1, Heather N. Burbank1, Gary F. Alsofrom1, Grant J. Linnell1 and Christopher G. Filippi1

1 Department of Radiology, Fletcher Allen Health Care, University of Vermont School of Medicine, 111 Colchester Ave., Burlington, VT 05401.

OBJECTIVE. The purpose of our study was to determine the discrepancy rates of radiology residents' interpretations of emergent CT angiography (CTA) studies of the neck and circle of Willis and to assess any adverse clinical outcomes.

MATERIALS AND METHODS. Five hundred thirty-eight CTA studies (287 circle of Willis and 251 neck) ordered emergently after hours and given preliminary readings by radiology residents from January 1, 2006, through December 31, 2007, were retrospectively reviewed. Discrepancies between the interpretations of radiology residents and the final reports of neuroradiology attending physicians were classified as either false-negatives (failure to recognize abnormalities) or false-positives (misinterpreting normal scans as abnormal). Discrepancies that could affect patient care or clinical care were considered major.

RESULTS. Overall, the discrepancy rate was 13.6% for circle of Willis CTA and 13.5% for neck CTA. The misinterpretation rate of first-year residents was 19.5%, which was statistically significant compared with more senior-level residents (p = 0.05). There were 57 false-negative interpretations. The most common misses were stenosis greater than 50% (n = 16) and aneurysm (n = 15), and the most common false-positive was overcalling a potential intracranial aneurysm (n = 7). No adverse clinical outcomes were detected.

CONCLUSION. The discrepancy rate between interpretations by on-call radiology residents and attending physicians of neuroradiology CTA studies was higher than expected at 13.6%, with a statistically significant greater miss rate among the most junior residents, which may be mitigated by recent changes with respect to the radiology residents' overnight call. No adverse clinical outcome was detected.

Keywords: circle of Willis • CT angiography • neck • practice-based learning • radiology residency call • systems-based practices