AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Google Scholar
Right arrow Articles by Gur, D.
Right arrow Articles by Bandos, A. I.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gur, D.
Right arrow Articles by Bandos, A. I.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.2031
AJR 2009; 193:586-591
© American Roentgen Ray Society


Original Research

Digital Breast Tomosynthesis: Observer Performance Study

David Gur1, Gordon S. Abrams2, Denise M. Chough2, Marie A. Ganott2, Christiane M. Hakim2, Ronald L. Perrin2, Grace Y. Rathfon2, Jules H. Sumkin2, Margarita L. Zuley2 and Andriy I. Bandos3

1 Radiology Imaging Research, Department of Radiology, University of Pittsburgh, 3362 Fifth Ave., Rm. 223 FARP Bldg., Pittsburgh, PA 15213.
2 Department of Radiology, Magee-Womens Hospital, Pittsburgh, PA.
3 Department of Biostatistics, Graduate School of Public Health, University of Pittsburgh, Pittsburgh, PA.

OBJECTIVE. The purpose of this study was to compare in a retrospective observer study the diagnostic performance of full-field digital mammography (FFDM) with that of digital breast tomosynthesis.

MATERIALS AND METHODS. Eight experienced radiologists interpreted images from 125 selected examinations, 35 with verified findings of cancer and 90 with no finding of cancer. The four display conditions included FFDM alone, 11 low-dose projections, reconstructed digital breast tomosynthesis images, and a combined display mode of FFDM and digital breast tomosynthesis images. Observers rated examinations using the screening BI-RADS rating scale and the free-response receiver operating characteristic paradigm. Observer performance levels were measured as the proportion of examinations prompting recall of patients for further diagnostic evaluation. The results were presented in terms of true-positive fraction and false-positive fraction. Performance levels were compared among the acquisitions and reading modes. Time to view and interpret an examination also was evaluated.

RESULTS. Use of the combination of digital breast tomosynthesis and FFDM was associated with 30% reduction in recall rate for cancer-free examinations that would have led to recall if FFDM had been used alone (p < 0.0001 for the participating radiologists, p = 0.047 in the context of a generalized population of radiologists). Use of digital breast tomosynthesis alone also tended to reduce recall rates, an average of 10%, although the observed decrease was not statistically significant (p = 0.09 for the participating radiologists). There was no convincing evidence that use of digital breast tomosynthesis alone or in combination with FFDM results in a substantial improvement in sensitivity.

CONCLUSION. Use of digital breast tomosynthesis for breast imaging may result in a substantial decrease in recall rate.

Keywords: digital breast tomosynthesis • digital mammography • observer performance study • recall rate


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
radtechHome page
P. BALDWIN
Digital Breast Tomosynthesis
Radiol. Technol., September 1, 2009; 81(1): 57M - 74M.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS