AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Jansen, S. A.
Right arrow Articles by Newstead, G. M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jansen, S. A.
Right arrow Articles by Newstead, G. M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.2025
AJR 2009; 193:832-839
© American Roentgen Ray Society


Original Research

Kinetic Curves of Malignant Lesions Are Not Consistent Across MRI Systems: Need for Improved Standardization of Breast Dynamic Contrast-Enhanced MRI Acquisition

Sanaz A. Jansen1, Akiko Shimauchi1, Lindsay Zak1, Xiaobing Fan1, Abbie M. Wood1, Gregory S. Karczmar1 and Gillian M. Newstead1

1 All authors: Department of Radiology, University of Chicago, 5841 S Maryland Ave., MC 2026, Chicago, IL 60637.

OBJECTIVE. The purpose of this study was to compare MRI kinetic curve data acquired with three systems in the evaluation of malignant lesions of the breast.

MATERIALS AND METHODS. The cases of 601 patients with 682 breast lesions (185 benign, 497 malignant) were selected for review. The malignant lesions were classified as ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), and other. The dynamic MRI protocol consisted of one unenhanced and three to seven contrast-enhanced images acquired with one of three imaging protocols and systems. An experienced radiologist analyzed the shapes of the kinetic curves according to the BI-RADS lexicon. Several quantitative kinetic parameters were calculated, and the kinetic parameters of malignant lesions were compared across the three systems.

RESULTS. Imaging protocol and system 1 were used to image 304 malignant lesions (185 IDC, 62 DCIS); imaging protocol and system 2, 107 lesions (72 IDC, 21 DCIS); and imaging protocol and system 3, 86 lesions (64 IDC, 17 DCIS). Compared with those visualized with imaging protocols and systems 1 and 2, IDC lesions visualized with imaging protocol and system 3 had significantly less initial enhancement, longer time to peak enhancement, and a slower washout rate (p < 0.004). Only 47% of IDC lesions imaged with imaging protocol and system 3 exhibited washout type curves, compared with 75% and 74% of those imaged with imaging protocols and systems 2 and 1, respectively. The diagnostic accuracy of kinetic analysis was lowest for imaging protocol and system 3, but the difference was not statistically significant.

CONCLUSION. The kinetic curve data on malignant lesions acquired with one system showed significantly lower initial contrast uptake and a different curve shape in comparison with data acquired with the other two systems. Differences in k-space sampling, T1 weighting, and magnetization transfer effects may be explanations for the difference.

Keywords: breast • dynamic contrast-enhanced MRI • malignant lesions • kinetic parameters • standardization


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Roentgen Ray Society.