AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, C. K.
Right arrow Articles by Kim, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, C. K.
Right arrow Articles by Kim, B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.09.3004
AJR 2010; 194:W33-W37
© American Roentgen Ray Society


Original Research

High-b-Value Diffusion-Weighted Imaging at 3 T to Detect Prostate Cancer: Comparisons Between b Values of 1,000 and 2,000 s/mm2

Chan Kyo Kim1, Byung Kwan Park1 and Bohyun Kim2

1 Department of Radiology and Center for Imaging Science, Sungkyunkwan University School of Medicine, Samsung Medical Center, 50 Ilwon-dong, Kangnam-gu, Seoul, Republic of Korea.
2 Department of Radiology, Mayo Clinic College of Medicine, Rochester, MN.

OBJECTIVE. The objective of our study was to investigate the diagnostic performance of 3-T MRI of the prostate using diffusion-weighted imaging (DWI) with high b values (1,000 and 2,000 s/mm2) and a phased-array coil in predicting localized prostate cancer.

MATERIALS AND METHODS. Forty-eight patients underwent single-shot echo-planar DWI at 3 T, followed by radical prostatectomy. DWI was performed at high b values of 1,000 and 2,000 s/mm2. Apparent diffusion coefficient (ADC) maps were analyzed by visual and quantitative assessment for tumor and benign tissue in the peripheral and transition zones. The visual and quantitative results of ADC maps obtained at b values of 1,000 and 2,000 s/mm2 were compared with the histopathologic findings.

RESULTS. To predict localized prostate cancer, the sensitivity of ADC maps obtained at a b value of 1,000 versus 2,000 s/mm2 was 88% and 71%, respectively, and the accuracy was 89% and 86% (p < 0.01). The mean ADC values of tumors in both the peripheral and transition zones were significantly lower than those of benign tissues at both b values of 1,000 and 2,000 s/mm2 (p < 0.001).

CONCLUSION. Prostate DWI performed at 3 T using high b values was able to improve differentiation of tumors from benign tissue. DWI performed using a b value of 1,000 s/mm2 was more sensitive and more accurate in predicting localized prostate cancer than DWI performed using a b value of 2,000 s/mm2.

Keywords: apparent diffusion coefficient • diffusion-weighted imaging • high b value • MRI • prostate carcinoma