AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Hendrick, R. E.
Right arrow Articles by Gatsonis, C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hendrick, R. E.
Right arrow Articles by Gatsonis, C.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
DOI:10.2214/AJR.08.2114
AJR 2010; 194:362-369
© American Roentgen Ray Society


Original Research

Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening Trial

R. Edward Hendrick1, Etta D. Pisano2, Alice Averbukh1, Catherine Moran1,3, Eric A. Berns1,4, Martin J. Yaffe5, Benjamin Herman6, Suddhasatta Acharyya6 and Constantine Gatsonis6

1 Department of Radiology, University of Colorado–Denver, Anschutz Medical School, 12700 E 19th Ave., Mail Stop C-278, RC2/1205, Aurora, CO 80045.
2 Department of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC.
3 Present address: Department of Radiology, University of Wisconsin, Madison, WI.
4 Present address: Department of Radiology, Denver Health Medical Center, Denver, CO.
5 Department of Medical Imaging and Biophysics, University of Toronto, Toronto, ON, Canada.
6 Center for Statistical Sciences, Brown University, Providence, RI.

OBJECTIVE. The purpose of our study was to compare the technical performance of full-field digital mammography (FFDM) and screen-film mammography.

MATERIALS AND METHODS. The American College of Radiology Imaging Network Digital Mammographic Imaging Screening Trial enrolled 49,528 women to compare FFDM and screen-film mammography for screening. For quality assurance purposes, technical parameters including breast compression force, compressed breast thickness, mean glandular dose, and the number of additional views needed for complete breast coverage were recorded and analyzed for both FFDM and screen-film mammography on approximately 10% of study subjects at each site.

RESULTS. Technical data were compiled on 5,102 study subjects at 33 sites. Clean data were obtained for 4,366 (88%) of those cases. Mean compression force was 10.7 dN for screen-film mammography and 10.1 dN for FFDM (5.5% difference, p < 0.001). Mean compressed breast thickness was 5.3 cm for screen-film mammography and 5.4 cm for FFDM (1.7% difference, p < 0.001). Mean glandular dose per view averaged 2.37 mGy for screen-film mammography and 1.86 mGy for FFDM, 22% lower for digital than screen-film mammography, with sizeable variations among digital manufacturers. Twelve percent of screen-film mammography cases required more than the normal four views, whereas 21% of FFDM cases required more than the four normal views to cover all breast tissue. When extra views were included, mean glandular dose per subject was 4.15 mGy for FFDM and 4.98 mGy for screen-film mammography, 17% lower for FFDM than screen-film mammography.

CONCLUSION. Our results show that differences between screen-film mammography and FFDM in compression force and indicated compressed breast thickness were small. On average, FFDM had 22% lower mean glandular dose than screen-film mammography per acquired view, with sizeable variations in average FFDM doses by manufacturer.

Keywords: breast • cancer • digital mammography • mammography • radiation dose • technology


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2010 by the American Roentgen Ray Society.