AJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vernhet, H.
Right arrow Articles by Dauzat, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vernhet, H.
Right arrow Articles by Dauzat, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

Changes in Wall Mechanics After Endovascular Stenting in the Rabbit Aorta

Comparison of Three Stent Designs

Hélène Vernhet1, Roland Demaria1, Jean Marie Juan1, Marie Claire Oliva-Lauraire1, Jean Paul Sénac2 and Michel Dauzat1

1 Laboratory of Cardiovascular Physiology, Montpellier I University, Faculty of Medicine, Av. Kennedy, Nîmes F 30907, France.
2 Department of Thoracic and Cardiovascular Imaging, Montpellier University Hospital, 34295-Montpellier Cedex, France.



View larger version (10K):

[in a new window]
 
Fig. 1. Drawing shows location of diameter and flow measurements on rabbit aorta, at stent level (S), upstream (U), and downstream (D) from stent.

 


View larger version (17K):

[in a new window]
 
Fig. 2A. Comparative presentations of diameter (d), systolic diameter change ({Delta}d), blood pressure (P), and ECG, at level of stent, before and after stenting. Recordings show Wallstent (Schneider, Bülach, Switzerland) (rabbit 2) (A), Palmaz stent (Johnson & Johnson, Warren, NJ) (rabbit 6) (B), and Jostent (Jomed, Rangendingen, Germany) (rabbit 12) (C). Note decrease in systolic diameter change after stenting in all instances.

 


View larger version (19K):

[in a new window]
 
Fig. 2B. Comparative presentations of diameter (d), systolic diameter change ({Delta}d), blood pressure (P), and ECG, at level of stent, before and after stenting. Recordings show Wallstent (Schneider, Bülach, Switzerland) (rabbit 2) (A), Palmaz stent (Johnson & Johnson, Warren, NJ) (rabbit 6) (B), and Jostent (Jomed, Rangendingen, Germany) (rabbit 12) (C). Note decrease in systolic diameter change after stenting in all instances.

 


View larger version (16K):

[in a new window]
 
Fig. 2C. Comparative presentations of diameter (d), systolic diameter change ({Delta}d), blood pressure (P), and ECG, at level of stent, before and after stenting. Recordings show Wallstent (Schneider, Bülach, Switzerland) (rabbit 2) (A), Palmaz stent (Johnson & Johnson, Warren, NJ) (rabbit 6) (B), and Jostent (Jomed, Rangendingen, Germany) (rabbit 12) (C). Note decrease in systolic diameter change after stenting in all instances.

 

Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Roentgen Ray Society.