AJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maintz, D.
Right arrow Articles by Fischbach, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maintz, D.
Right arrow Articles by Fischbach, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

Revealing In-Stent Stenoses of the Iliac Arteries: Comparison of Multidetector CT with MR Angiography and Digital Radiographic Angiography in a Phantom Model

David Maintz1, Bernd Tombach, Kai-Uwe Juergens, Stefanie Weigel, Walter Heindel and Roman Fischbach

1 All authors: Department of Clinical Radiology, University of Münster, Albert-Schweitzer-Str. 33, 48129 Münster, Germany.



View larger version (22K):

[in a new window]
 
Fig. 1. Digital radiographic angiogram shows exact delineation of stenoses inside stents. Stents are shown from left to right control, Strecker Tantalum (Boston Scientific Europe, Paris, France), Strecker Nitinol (Boston Scientific Europe), ZA-Stent (Cook, Moenchengladbach, Germany), Symphony (Boston Scientific Europe), Easy Wallstent (Boston Scientific Europe), Perflex (Cordis, Miami, FL), and Palmaz P394 (Cordis).

 


View larger version (42K):

[in a new window]
 
Fig. 2. Multidetector CT angiogram shows dependency of stenosis delineation on stent type. Stents appear in same order as in Figure 1: control, Strecker Tantalum (Boston Scientific Europe, Paris, France), Strecker Nitinol (Boston Scientific Europe), ZA-Stent (Cook, Moenchengladbach, Germany), Symphony (Boston Scientific Europe), Easy Wallstent (Boston Scientific Europe), Perflex (Cordis, Miami, FL), and Palmaz P394 (Cordis). Complete obscurity of stenosis is caused by Strecker tantalum stent. In other stents (steel, nitinol, and cobalt-based alloy), stenoses are delineated.

 


View larger version (22K):

[in a new window]
 
Fig. 3. MR angiogram shows dependency of stenosis delineation on stent types. Stents appear in same order as in Figure 1: control, Strecker Tantalum (Boston Scientific Europe, Paris, France), Strecker Nitinol (Boston Scientific Europe), ZA-Stent (Cook, Moenchengladbach, Germany), Symphony (Boston Scientific Europe), Easy Wallstent (Boston Scientific Europe), Perflex (Cordis, Miami, FL), and Palmaz P394 (Cordis). Only minor artifacts are caused by Strecker tantalum stent. Good stenosis delineation is shown for Strecker nitinol, ZA-Stent, and Easy Wallstent. Limitations in stenoses delineation are caused by signal decrease inside Symphony and Perflex stents. Stenosis is not visible in Palmaz P394 stent.

 