AJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kroft, L. J. M.
Right arrow Articles by Geleijns, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kroft, L. J. M.
Right arrow Articles by Geleijns, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease

Lucia J. M. Kroft1, Wouter J. H. Veldkamp1, Bart J. A. Mertens2, Mireille V. Boot1 and Jacob Geleijns1

1 Department of Radiology, Leiden University Medical Center, Albinusdreef 2, Leiden, The Netherlands 2333 ZA.
2 Department of Medical Statistics, Leiden University Medical Center, Leiden, The Netherlands 2333 ZA.



View larger version (146K):

[in a new window]
 
Fig. 1 Digital radiograph showing appearance of simulated lesions on anthropomorphic chest phantom.

A, This part of image shows interstitial-nodular disease. Arrowheads indicate two of many small nodules.

B, This part of image shows interstitial-linear disease.

C, This part of image shows tumor. Image contrast settings were optimized for highlighting lesions.

 


View larger version (7K):

[in a new window]
 
Fig. 2 Calculated patient effective dose and number of simulated lesions detected in anthropomorphic chest phantom for eight digital chest systems in clinical practice.

 

Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Roentgen Ray Society.