AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ramaswamy, M. R.
Right arrow Articles by vanSonnenberg, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ramaswamy, M. R.
Right arrow Articles by vanSonnenberg, E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2000; 174:617-622
© American Roentgen Ray Society


Continuous Speech Recognition in MR Imaging Reporting

Advantages, Disadvantages, and Impact

Mohan R. Ramaswamy1,2, Gregory Chaljub1, Oliver Esch1, Donald D. Fanning1 and Eric vanSonnenberg1,3

1 Department of Radiology, University of Texas Medical Branch, 301 University Blvd., Galveston, TX 77555-0465.
2 Present address: Department of Radiology, University of California, S.F.G.H. (Bldg. NH, Rm. G100), 1001 Potrero Ave., San Francisco, CA 94110.
3 Present address: Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02115.

Received February 11, 1999; accepted after revision August 10, 1999.

 
Presented at the annual meeting of the American Roentgen Ray Society, San Francisco, April—May 1998.

Address correspondence to G. Chaljub.


Abstract
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
OBJECTIVE. Our objective was to describe our experience with a commercially available continuous speech recognition system, highlighting the advantages, disadvantages, and costs compared with those of conventional transcription for MR imaging reports.

MATERIALS AND METHODS. Data from 5072 reports generated in our MR imaging section during a 9-month period after the implementation of a commercial continuous speech recognition system were compared with 4552 reports produced during the same period 1 year earlier. Information pertaining to the use of continuous speech recognition, report turnaround time, word recognition rate, report appearance, and equipment costs was collected.

RESULTS. After its system installation, continuous speech recognition was used to dictate 81.8% of all reports. The mean report turnaround time decreased from 87.8 to 43.6 hr, and report availability at 24 hr increased from 10.5% to 62.5%. The system was found to have an average word recognition accuracy of 92.7% for spontaneous dictation. Mean report length declined from 95 to 60 words, with an increase in spacing errors from 0.3 to 8.0 per 1000 words and a decrease in spelling errors from 3.0 to 0.8 per 1000 words. Initial hardware and software costs were approximately $10,000, compared with a yearly cost of $12,000 for human transcription.

CONCLUSION. Although the technology is still evolving and was evaluated in its earliest implementation stages, continuous speech recognition nonetheless markedly improved report turnaround time and proved cost-effective.


Introduction
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Speech recognition technology allows a computer to transcribe dictation, eliminating the need for a human transcriptionist. The use of computerized speech recognition in radiology reporting was described as early as 1981 [1]. Early speech recognition systems remained unpopular because of numerous limitations: vocabularies were limited to a few hundred or thousand words; several hours were required for a user to train the system to his or her voice; and most importantly, only discrete speech was allowed [1,2,3]. Discrete speech recognizers require the user to separate each word with a 100-200 msec pause (i.e., "speak...like...this"), a process that is awkward, time-consuming, user-unfriendly, and doomed to failure.

More recent articles have described systems capable of recognizing larger vocabularies with less training [4, 5]; however, these systems still require discrete speech. Only recently has computer hardware and software technology improved to the point that affordable commercial continuous speech recognition systems are now available for radiology dictation [6, 7]. By enabling the radiologist to speak at a more natural and faster pace, these systems offer a palatable alternative to discrete speech recognizers.

Such a commercial continuous speech recognition system has been implemented in the MR imaging section of our radiology department for 9 months at the time of this writing. The purpose of this article is to describe our initial experience with the system in daily clinical use and to identify its main advantages, disadvantages, and costs compared with those of more conventional transcription methods. Considering these data, we provide practical recommendations for the appropriate application of this new technology.


Materials and Methods
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Equipment
Our radiology department serves a 970-bed academic center containing four MR scanners. The MR imaging section is staffed by a combination of residents, fellows, and faculty responsible for the interpretation of every adult MR imaging examination performed. Although interpretation is usually performed between 8 A.M. and 5 P.M. on weekdays only, examinations are routinely scheduled and performed during the evenings and on weekends.

Before February 1997, all dictation in the MR imaging section was performed using a single conventional dictation station (VoiceWriter; Lanier, Atlanta, GA). Similar dictation stations are located throughout the department; all are linked to a central archive in which dictations are stored until they can be transcribed by a member of the department's central transcription pool. At that time, this pool consisted of nine transcriptionists responsible for more than 20,000 reports a month.

In February 1997, a commercially available continuous speech recognition hardware and software package (MedSpeak/Radiology version 1.2; International Business Machines, Armonk, NY) was installed in the MR imaging section. This system contains a 25,000-word vocabulary designed specifically for the dictation of radiology reports, with the capability to learn new words as needed. Before using the system, each radiologist underwent an individualized training session in which he or she learned the basic commands needed to dictate, edit, and sign reports. Included in this session was a process known as enrollment, in which the user trained the system to his or her voice by dictating 200 standard sentences. The session took approximately 1 hr and was conducted by a member of the hospital's information system service.

Both the transcription pool and the continuous speech recognition unit are interfaced over a local area network to the department's radiology information system (IDXrad version 9.0; IDXrad, Burlington, VT). This radiology information system allows referring clinicians to obtain access to reports from terminals located throughout the hospital as soon as they are transcribed. In addition, the radiology information system stores a variety of information about all radiologic examinations performed in the department.

Data Acquisition
The radiology information system was used retrospectively to obtain a list of all adult MR imaging examinations performed during the 9-month period after the installation of continuous speech recognition (February 1-October 31, 1997). Additional data acquired for each examination include the time of examination completion, the time of report transcription, the report length, the dictating and signing radiologists, and whether the report was transcribed by a transcriptionist or the continuous speech recognition system. Similar data were acquired for all adult MR imaging examinations performed within the same 9-month period of the preceding year (February 1-October 31, 1996).

Available information regarding the cost of the equipment used in this study was also obtained. In addition, subjective information and ideas were informally collected from radiologists at weekly users' meetings and departmental meetings to gauge their acceptance of the system and are presented in this article.

Radiologists
During the 1996 study period, 4552 adult MR imaging reports were dictated by 39 radiologists; during the 1997 study period, 5072 reports were dictated by 33 radiologists. Because of the change of house staff between the two periods, 44 different radiologists were involved in the study overall, with 17 radiologists (three faculty and 14 house staff) accounting for 90% of all dictation. These radiologists represented a wide range of radiology experience (residents, fellows, and faculty), computer experience, and speech patterns. Two of the three neuroradiology faculty were born abroad, with English learned as a second language.

Turnaround Time
The report generation process at our institution was divided into six component parts (Fig. 1). Although the most direct measure of the effect of continuous speech recognition would be the time between report dictation (step 3) and report finalization (step 6), the radiology information system records only the time of examination completion (step 1), the time of report transcription (step 4), and the time of report finalization (step 6). During the 1997 study period, a program was instituted to expedite the signing of reports through electronic monitoring of each radiologist's signing habits. As a result, radiologists became much more aware of the need to edit and sign reports expeditiously. Because this action would spuriously improve the time of report finalization (cosigned by a staff radiologist) for 1997, we decided to measure turnaround time from the time of examination completion (step 1) to the time of report transcription and preliminary report availability (step 4).



View larger version (24K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 1. —Flow chart shows step-by-step breakdown of report generation process at our institution. For this study, turnaround time was measured from completion of examination (step 1) to availability of preliminary report (step 4). Note that preliminary report has immediate access in IDXrad ([radiology information systems] IDX Systems, Burlington, VT) for clinicians.

 

On the basis of this analysis, turnaround time may be expressed as time1-2 + time2-3 + time3-4 (Fig. 1). Of these factors, continuous speech recognition would be expected to influence only the time between report dictation and report transcription (time3-4). To ensure that the implementation of continuous speech recognition was the only factor that would significantly influence the turnaround times between the two study periods, the other factors that affect turnaround time were examined. The time between examination completion and the delivery of images to the reading room (time1-2) was considered minimal and was therefore ignored.

The time (time2-3) between the delivery of images to the reading room and their interpretation is influenced by three factors: the frequency of interpretation sessions, the number of examinations performed on weeknights and weekends (because these off-hour studies are not interpreted officially until the next working day), and the number of examinations removed by clinicians before they can be interpreted (because these are not usually recovered or reprinted and interpreted until several days or weeks later). The frequency of interpretation sessions was constant and was ignored. The proportion of off-hours examinations remained similar, with 45% and 42% of examinations performed during off-hours in 1996 and 1997, respectively. The number of examinations removed by clinicans also remained similar, with 1.85% of examinations taken and left not interpreted for an average of 5.0 weeks in 1996, and 1.46% of examinations taken and left not interpreted for an average of 5.7 weeks in 1997. These removed examinations raised both the 1996 and 1997 mean turnaround times by approximately 14 hr. Because these values remained similar between the two study periods, we feel confident in attributing any changes in turnaround time primarily to the introduction and use of continuous speech recognition.

Accuracy
System accuracy was assessed by measuring its word recognition rate [8]. A representative sample of five radiologists (one faculty, one fellow, one fourth-year resident, and two third-year residents) was chosen on the basis of their availability on the MR service. All five radiologists are Americanborn speakers of English with no significant accent or speech impediment, and all underwent the routine training and enrollment process. Three radiologists had extensive system experience (dictating several hundred reports each), whereas two radiologists (the third-year residents) had never used the system for actual report dictation.

The radiologists were asked to spontaneously dictate cases using continuous speech recognition while being observed by two of the authors. (The radiologists were aware of being observed.) Each was observed for a single readout session during which 15-20 cases (mean, 16) were dictated. For each radiologist, the total number of words spoken and the number of words correctly recognized by the system were recorded. Subsequently, a 124-word test report was developed that contained a variety of words commonly used in MR dictation (Appendix 1). Each radiologist was asked to read this test report three times, and a similar determination of word recognition rate was performed. All testing was performed in our designated MR reading room, with no attempt made to control background noise or interruptions.


View this table:
[in this window]
[in a new window]

 
APPENDIX 1: MR Test Report (124 words)

 

For the purposes of accuracy determination, punctuation marks and formatting commands (e.g., "new paragraph") were considered words. Numbers, dates, and other compound words were counted as single words, regardless of the number of utterances it took to produce them. A word was considered correctly recognized only if it was transcribed exactly as intended. Errors caused by mispronunciations, homonyms (words with similar pronunciations but different spellings, such as "to," "too," and "two"), and out-of-vocabulary words (words not included in the computer's 25,000-word vocabulary) were considered incorrect.

Report Appearance
Data were collected from the radiology information system regarding the length (in lines, words, and characters) of each report dictated during both the continuous speech recognition and the conventional transcription study periods. Additionally, 100 reports from each period were chosen randomly and reviewed by one of the authors for word errors. These errors were classified as errors in spacing (i.e., more than one space between words), spelling, or word omission or duplication; these data were then scored per 1000 words of report text.


Results
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
During the course of the 1997 study period, radiologists were encouraged to exclusively use the continuous speech recognition system. The conventional dictation system was used only during the enrollment stage and during temporary malfunction of the continuous speech recognition system. Malfunction usually occurred because of a network outage between the main server and the local continuous speech recognition system; such malfunctions were usually corrected within an hour. We found a strong trend toward the use of continuous speech recognition (Fig. 2). The radiologists used the continuous speech recognition system for all reports—normal reports as well as complex or lengthy reports. The overall use of continuous speech recognition during the entire study period was 81.8%, rising to 92.8% during the last 3 months.



View larger version (10K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 2. —Graph shows monthly usage of continuous speech recognition (solid line) versus conventional dictation (broken line) in MR imaging reporting.

 

We also found marked improvement in report availability after the implementation of continuous speech recognition (Fig. 3). Most notably, report availability at 24 hr increased from 10.5% to 62.5% (Table 1). The mean turnaround time declined from 87.8 hr in 1996 to 43.6 hr in 1997, a 50.3% reduction (Table 1). During the last 3 months of the 1997 study period, in which continuous speech recognition use peaked, these figures improved further, with a mean turnaround time of 32.3 hr and a 24-hr report availability of 71.1%.



View larger version (11K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 3. —Graph shows time until MR report availability before (broken line) and after (solid line) implementation of continuous speech recognition.

 

View this table:
[in this window]
[in a new window]

 
TABLE 1 Report Availability Before (1996) and After (1997) Implementation of Continuous Speech Recognition

 

During spontaneous dictation, the word recognition rate of our continuous speech recognition system for the five radiologists tested varied from 91.9% to 93.3%, with a mean accuracy of 92.7% (n = 4689 words spoken in 80 reports) (Table 2). A typical report examined during this testing is shown in Appendix 2. During reading of the standardized MR test report (Appendix 1), a higher word recognition rate was achieved, varying from 94.1% to 98.9% with a mean of 96.5% (n = 1860 words spoken in 15 readings). After implementation of continuous speech recognition, the mean report length declined by 37%, from 95 words (13.6 lines) to 60 words (7.9 lines) (Table 3). Irregular spacing increased from 0.3 (n = 9266 words) to 8.0 per 1000 words (n = 6297 words), and word omissions and duplications increased from 0.3 to 1.0 per 1000 words. However, spelling errors did decrease from 3.0 to 0.8 per 1000 words.


View this table:
[in this window]
[in a new window]

 
TABLE 2 Word Recognition Rate of Continuous Speech Recognition for Five Radiologists

 

View this table:
[in this window]
[in a new window]

 
APPENDIX 2: Sample Reports

 

View this table:
[in this window]
[in a new window]

 
TABLE 3 Appearance of Reports Dictated with Conventional Dictation and Transcription (CDT) Versus Continuous Speech Recognition (CSR)

 

The equipment cost of our continuous speech recognition system was approximately $10,000 (Table 4). Because system maintenance and training are performed by several existing members of our hospital's information system department (occupying only a small amount of each employee's time), we could not accurately estimate these costs. Thus, in the future further cost analysis is recommended. Before the implementation of continuous speech recognition, MR report transcription occupied 5.5% of the effort of the entire transcription pool (on a per-character basis), which has an annual operating budget of $220,000. On the basis of these figures, we estimate the annual cost of human transcription for our MR imaging section to be $12,000.


View this table:
[in this window]
[in a new window]

 
TABLE 4 Equipment and Costs of Our Continuous Speech Recognition System

 


Discussion
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Advantages of Continuous Speech Recognition
After its first month of implementation, continuous speech recognition clearly became the preferred method of MR dictation, accounting for 81.8% of all reports dictated and 92.8% of all reports in the final 3 months. The radiologists using the system cited improved turnaround time as the primary impetus for its use, a sentiment that has been echoed by referring clinicians and hospital administrators. These latter groups are ever more important because managed care competition and issues regarding the value added by radiology require expeditious throughput.

Because continuous speech recognition transcribes reports in real-time (i.e., as they are being dictated), the third and fourth steps of the report generation process are combined, eliminating a significant amount of time (time3-4) that would have transpired with conventional dictation. A tangible benefit to our radiologists of the improvement in turnaround time has been a virtual elimination of incoming telephone calls for preliminary reports (which were cited as having been time-consuming). In contrast, a report by Seltzer et al. [9] published in 1997 examined a different manufacturer's technology. These researchers did not find continuous speech recognition to be an effective component of a total quality approach to reducing turnaround time in a large teaching hospital. This discrepancy in findings suggests that significant differences may exist in various continuous speech recognition technologies or dictating patterns or both.

Because a transcribed report is available to the dictating radiologist as the images are being read, he or she can edit and sign the report immediately [2, 4, 6], combining step 5 (when the report is dictated by a house staff radiologist) or steps 5 and 6 (when the report is dictated by faculty) into the dictation process; this can be expected to eliminate a significant amount of time (time4-5 and time5-6) [7]. The resulting timesaving was not evaluated in this study because of the confounding effect of other programs recently instituted to encourage radiologists to sign their reports expeditiously.

Although a variety of measures have been proposed to reduce turnaround time [9], continuous speech recognition has a distinct benefit in that a report can be edited and signed on-line on a case-by-case basis (not in a batch mode) while the images are still being viewed [6]. We feel it is reasonable to expect that such immediacy will lead to a reduction in major dictation and transcription errors (i.e., those that change the meaning of a report) as have occurred when reports were not edited until several hours or days after the images were viewed. Examples of such errors encountered include patient misidentification, misstatements by the radiologist (such as transposition of the words "right" and "left" during dictation), and misinterpretation of a critical word by the transcriptionist. Immediate editing and signing is considered a great benefit of the continuous speech recognition system, obviating correcting and signing reports afterward as compared with conventional transcription.

Disadvantages of Continuous Speech Recognition
The major objection given by our radiologists for not using continuous speech recognition is an increased editing burden. The amount of editing required by a continuous speech recognition system may be estimated by its accuracy rate [6]. Although the 92.7% word recognition rate of our system may seem high, all five of the radiologists examined subjectively thought that this value belied the amount of editing required [4]. Actual editing times were not measured, because they varied widely depending on a radiologist's dictation style (i.e., report length and complexity), familiarity with computer word processing, ability to type, and tolerance for minor errors (i.e., those that do not change the meaning of a report) [6]. In addition, most users found the editing process to be distracting from image interpretation [1, 10] and wanted a user interface more closely simulating conventional dictation [7]. This finding suggests that any changes in practice patterns should be minimized for a smooth transition.

Spontaneous speech is rife with what we will refer to in this article as "disfluencies" (e.g., stammering, slurring, hesitation, filled pauses, repairs, fragments, and interruptions). Human listeners (particularly transcriptionists) are accustomed to these disfluencies and can accommodate them. However, continuous computer speech recognition systems often interpret these sounds literally, resulting in reduced accuracy [8, 11, 12]. This fact is reflected in the higher word recognition rate (96.5%) achieved by our radiologists when reading the standardized test report. To minimize disfluencies during dictation, we suggest to our residents that they thoughtfully formulate the entire report before beginning to speak, rather than using a "thinking out loud" approach. Additionally, these data suggest that one should be cautious when evaluating a continuous speech recognition system using a prepared text because diminished accuracy is likely to be encountered during actual practice. Another limiting factor of the continuous speech recognition system is that a minor illness such as pharyngitis results in decreased accuracy.

With increased continuous speech recognition experience, an individual speaker's accuracy usually improves as he or she adapts his or her speech pattern to the system, and concurrently as the system adapts to the individual's respective speech pattern [8]. To eliminate this effect, two radiologists with no continuous speech recognition experience were included in our study, both of whom performed as well as the more experienced speakers.

A limitation of this study is that all five radiologists examined are American-born speakers of English with no significant accent or speech impediment. An extensive evaluation of a wide range of speakers would be useful in estimating the accuracy that could be expected by speakers with different backgrounds.

Presumably to accommodate for the increased amount of editing, our radiologists began to shorten their reports (by an average of 37%). This shortening was done primarily by minimizing the clinical history and technique sections and by limiting descriptive detail. In another study, the researchers found this forced conciseness to be beneficial [13], whereas other researchers found physicians were indignant at having to adapt their dictation style to accommodate a computer [10].

It has been suggested that a human transcriptionist performs significant functions in addition to rote transcription, including formatting and grammar correction, that continuous speech recognition systems are not yet capable of handling [6] (although transcriptionists do occasionally make spelling or omission errors, or cannot understand sections of dictated material). The subsequent transfer of this clerical burden to the radiologist could then be expected to lead to an increase in these types of errors. Our data verify this, showing a significant increase in spacing and wording errors after the switch to continuous speech recognition.

Spacing errors were primarily extra spaces between words that appear to accumulate during the editing process as radiologists unfamiliar with computer word processing delete words but not the adjacent space. Word omissions and duplications resulted from dictation that was not fluent. When questioned about their errors, most radiologists indicated they considered the errors minor and had either overlooked them or ignored them in the interest of time. The automatic spell-checking provided by the continuous speech recognition system did result in a significant decrease in spelling errors.

Costs of Continuous Speech Recognition
The costs of a continuous speech recognition installation can vary depending on the size of the practice and the preexisting infrastructure, including conventional dictation equipment, networks, computers, and personnel. A detailed cost analysis should therefore be performed before such an installation is considered. In our case, the start-up costs of the continuous speech recognition equipment were found to be favorable compared with those of human transcription, with the costs recovered in less than a year. A similar time for cost recovery was recently reported by Rosenthal et al. [7]. The maintenance of the continuous speech recognition system was provided by in-house hospital information system personnel, which is a cost to the hospital that was not directly measured in this initial study.

Recommendations
Although continuous speech recognition techniques hold great promise for the future of radiology transcription, at present the technology requires further evolution, with a need for increased accuracy, improved grammatical sense, and a more radiologist-friendly user interface. However, current commercial units (such as described here) do provide distinct benefits. Use of such a unit should be considered in environments in which one or more of the following circumstances exist: the current turnaround time is considered too long; there is a high demand for preliminary reports by radiologists or clinicians; reports are short or highly standardized (i.e., screening mammography); the radiologists involved are interested in using the system, are familiar with or willing to learn computer word processing, and speak clearly and succinctly, with background noise and interruptions kept to a minimum and significant computer expertise available.

In our own MR imaging section, this technology has proven to be viable and cost-effective. Because of the improved turnaround time, continuous speech recognition has all but replaced more traditional transcription methods. Our department's transcription pool decreased from nine individuals to one. A limitation of this study is the lack of specific data on cases imaged and reported during normal daily working hours. We believe that the mean turnaround time for such reports generated using continuous speech recognition would be much lower. The continuous speech recognition technology does occasionally malfunction, and a backup transcriptionist is recommended. Templates of common reports are being implemented in our department and are sure to expedite the reporting process even further.


Acknowledgments
 
We thank Ralph Farr, Tom Epley, and Beth Hill for their efforts in helping to install and maintain the equipment used in this study, and for training its users. We thank Laverne Earles for preparation of the manuscript.


References
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 

  1. Leeming BW, Porter D, Jackson JD, Bleich HL, Simon M. Computerized radiologic reporting with voice data-entry. Radiology 1981;138:585-588[Abstract/Free Full Text]
  2. Robbins AH, Horowitz DM, Srinivasan MK, et al. Speech-controlled generation of radiology reports. Radiology 1987;164:569-573[Abstract/Free Full Text]
  3. Robbins AH, Vincent ME, Shaffer K, Maietta R, Srinivasan MK. Radiology reports: assessment of a 5,000-word speech recognizer. Radiology 1988;167:853-855[Abstract/Free Full Text]
  4. Herman SJ. Accuracy of a voice-to-text personal dictation system in the generation of radiology reports. AJR 1995;165:177-180[Abstract/Free Full Text]
  5. Zemmel NJ, Park SM, Maurer EJ, Leslie LF, Edlich RF. Evaluation of voicetype dictation for Windows for the radiologist. Med Prog Technol 1997;21:177-180
  6. Schwartz LH, Kijewski P, Hertogen H, Roossin PS, Castellino RA. Voice recognition in radiology reporting. AJR 1997;169:27-29[Abstract/Free Full Text]
  7. Rosenthal DI, Chew FS, Dupuy DE, et al. Computer-based speech recognition as a replacement for medical transcription. AJR 1998;170:23-25[Abstract/Free Full Text]
  8. Makhoul J, Schwartz R. State of the art in continuous speech recognition. Proc Natl Acad Sci U S A 1995;92:9956-9963[Abstract/Free Full Text]
  9. Seltzer SE, Kelly P, Adams DF, et al. Expediting the turnaround of radiology reports in a teaching hospital setting. AJR 1997;168:889-893[Abstract/Free Full Text]
  10. Hansen GC, Falkenbach KH, Yaghmai I. Voice recognition system (letter). Radiology 1988;169:580[Free Full Text]
  11. Cohen PR, Oviatt SL. The role of voice input for human-machine communication. Proc Natl Acad Sci U S A 1995;92:9921-9927[Abstract/Free Full Text]
  12. Roe DB. Deployment of human-machine dialogue systems. Proc Natl Acad Sci U S A 1995;92:10017-10022[Abstract/Free Full Text]
  13. Dershaw DD. Voice-activated radiology reports (letter). Radiology 1988;167:284[Free Full Text]

Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
D. L. Weiss and C. P. Langlotz
Structured Reporting: Patient Care Enhancement or Productivity Nightmare?
Radiology, December 1, 2008; 249(3): 739 - 747.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S McGURK, K BRAUER, T V MACFARLANE, and K A DUNCAN
The effect of voice recognition software on comparative error rates in radiology reports
Br. J. Radiol., October 1, 2008; 81(970): 767 - 770.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ramaswamy, M. R.
Right arrow Articles by vanSonnenberg, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ramaswamy, M. R.
Right arrow Articles by vanSonnenberg, E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS