|
|
||||||||
Perspective |
1 Department of Radiology, University of Wisconsin Medical School, E3/311 Clinical Science Center, 600 Highland Ave., Madison, WI 53792-3252.
Received December 15, 2006; accepted after revision March 28, 2007.
Address correspondence to P. J. Pickhardt
(pj.pickhardt{at}hosp.wisc.edu).
OBJECTIVE. The purpose of this article is to detail an approach to CT colonographic screening that has evolved at one institution.
CONCLUSION. CT colonography is a rapidly advancing technology that has great potential for addressing a deadly but preventable disease—colorectal carcinoma. CT colonography is ideally suited for widespread screening of asymptomatic adults and has become an integral component of the screening efforts at my institution since local third-party coverage was initiated.
Keywords: colorectal cancer colorectal polyps CT colonography screening virtual colonoscopy
CT colonography (CTC), also called virtual colonoscopy, is ideally suited for population screening of asymptomatic adults. Colorectal cancer, despite being largely preventable or at least curable if detected early, remains a major killer because of poor adherence to existing screening strategies. CTC screening is less invasive, less time-consuming, and less expensive than optical colonoscopy and can be at least as effective [1-3]. At my institution, the use of a previously validated CT screening method paved the way for local third-party reimbursement for screening of persons without symptoms, which was initiated in April 2004 [1, 2]. Since that time, more than 4,000 asymptomatic adults have undergone screening, and the initial results indicate that we have improved our earlier techniques [2]. Unfortunately, the current lack of third-party coverage elsewhere has stalled the logical transition of CTC from a research tool and limited diagnostic test to a full-fledged examination for widespread population screening. However, expanded coverage and use of CTC screening are on the horizon.
This review details the technique and basic interpretive approach for CTC screening at my institution. Other practical issues, such as program setup, patient referral, third-party reimbursement, extracolonic findings, cost-effectiveness, and common diagnostic pitfalls, are described elsewhere [3-7]. This work is expected to serve as a template for radiologists who are interested in but not yet fully engaged in CTC screening.
CTC Technique
The basic concept behind successful CTC is straightforward: When a properly prepared and distended colon is imaged with MDCT, clinically relevant polyps can be readily detected with dedicated CTC software [8]. If all facets of a CTC examination (preparation, distention, MDCT scanning, and interpretation) are adequately addressed, effective evaluation is relatively easy. Although each technical component is discussed separately, it is crucial to recognize the interdependence of these factors. Any weak link can render the overall product ineffective. For example, even the best CTC software system will fail if colonic preparation or distention is inadequate. Similarly, optimal preparation and distention cannot compensate for an inadequate CTC software system or an ineffective interpretive approach.
Colonic Preparation
Robust colonic preparation for CTC is critical for accurate polyp detection
and involves both cleansing and tagging. My colleagues and I use a low-volume
CTC preparation with three basic components: a laxative for catharsis, dilute
barium for fecal tagging, and iodinated water-soluble contrast medium
(diatrizoate) for fluid tagging (Table
1). This 1-day preparation has been greatly simplified from the
one used in the Department of Defense screening trial and is generally well
tolerated [9]. We have not
encountered significant preparation-related complications. In addition to
ingesting the agents prescribed for the preparation, the patient maintains a
clear liquid diet the day before the examination. Because the preparation
includes both over-the-counter laxatives and prescription oral contrast
agents, we have our central pharmacy combine the constituents into a
convenient kit, which is mailed to patients or dispensed at a number of local
pharmacies [3].
|
The choice of laxative depends on the health status of the patient. Although the nurse coordinator was initially screening all patients to determine the most appropriate preparation [2], we have found it more efficient and logical to provide referring physicians with our guidelines and have them choose the best preparation for their patients. The laxative for our standard CTC bowel preparation is sodium phosphate, which is used in nearly 90% of cases and is well tolerated. Because of rare reported instances of acute phosphate nephropathy [10], we avoid the use of sodium phosphate by elderly patients with hypertension, particularly those taking angiotensin-converting enzyme inhibitors, and by patients with renal or cardiac insufficiency. We have found that a single 45-mL dose of sodium phosphate is as effective as a double dose [9] and brings our preparation into U.S. Food and Drug Administration (FDA) compliance. With regard to a noncathartic CTC preparation, a number of disadvantages will likely prevent this approach from becoming a stand-alone front-line screening solution [11].
For nearly all patients who should avoid sodium phosphate, magnesium citrate is an acceptable substitute. Because we find magnesium citrate somewhat less effective than sodium phosphate, we use two 296-mL doses. For severely compromised patients who cannot tolerate even mild fluid or electrolyte shifts, we resort to polyethylene glycol (PEG), which is given as a 4-L solution. Although the safety profile of polyethylene glycol is most favorable for patients with a tenuous condition, preparation with polyethylene glycol is associated with the poorest adherence because of the consistency and taste of the solution and the large volume that must be ingested. Fortunately, polyethylene glycol preparation is rarely necessary for screening CTC, accounting for less than 1% of cases at my institution.
Regardless of the laxative used, the dual oral contrast regimen remains constant, consisting of single doses of 2% weight/volume barium and diatrizoate. The complementary actions of these two contrast agents result in optimal preparation for CTC [12]. The rationale behind the specific order of the three components of the preparation is that the laxative provides catharsis for bulk removal of fecal material, the barium tags residual feces, and the diatrizoate serves the dual purpose of uniform fluid tagging and secondary catharsis [12]. In my opinion, the 30-40% weight/volume barium preparations are too dense for CTC and may cause difficulty during same-day colonoscopy. In my experience, 2% barium has not caused problems in more than 1,500 colonoscopic studies performed immediately after CTC [13]. The ionic iodinated contrast agent not only opacifies luminal fluid and has an effect some-what similar to that of cathartics but also helps emulsify residual solid feces. The last feature is critical because adherent feces can severely complicate primary 3D polyp detection. The limited experience with nonionic iodinated contrast material (e.g., iohexol) at my institution suggests that the greater palatability of the nonionic agent does not override the problem of a large amount of adherent residual fecal material.
Oral contrast tagging for CTC increases specificity by tagging residual fecal material (barium effect) and decreasing the amount of adherent feces (diatrizoate effect). It increases sensitivity by allowing polyp detection in opacified fluid (diatrizoate effect). A potential pitfall that has become an interpretive asset is the tendency for true soft-tissue polyps to retain a thin surface coating of contrast material [14], which serves as a beacon for detection (Fig. 1A, 1B, 1C, 1D). Given the improved performance characteristics associated with use of oral contrast material, my colleagues and I strongly endorse use of these agents for CTC screening. With regard to computer-aided detection, most algorithms were not developed with contrast tagging in mind. Going foward, this aspect of the imaging procedure must be addressed [15, 16].
|
|
|
|
My colleagues and I have found that automated CO2 delivery is the best distention technique. Nearly all reported perforations during CTC have involved the use of staff-controlled manual insufflation of room air. The risk of perforation with automated or patient-controlled distention methods approaches zero among asymptomatic adults [18]. With regard to both study quality (i.e., degree of distention) and postprocedural discomfort, we have found that dynamic CO2 delivery is superior to manual administration of room air [17]. Continuous low-pressure automated CO2 delivery appears to reduce colonic spasm, particularly in segments with advanced diverticular disease. Rapid resorption of CO2 through the colonic wall accounts for improved comfort after the procedure. The CT technologists at my institution unanimously prefer the automated CO2 technique over manual methods [17]. They cite a more clearcut point to begin scanning, a diminished need for coaching patients, and decreased operator dependence, which leads to more consistent results from technologist to technologist.
To maintain efficiency, the CT technologists at my institution are trained to independently perform the entire CTC examination, including placement of the rectal catheter and assessment of adequacy of distention. The radiologist is consulted for difficult or unusual situations, which allows more time for interpretation. Before beginning an examination, the technologist interviews the patient to determine the fidelity of preparation, and the patient is encouraged to use the restroom. After rectal catheter placement, the patient remains in the left lateral decubitus position for delivery of the initial 1-1.5 L of CO2 with the automated device (PROTOCO2L, E-Z-EM). To reduce the transient discomfort related to initial rectal distention, the equilibrium pressure is initially set to 20 mm Hg. The patient is then placed in the right lateral decubitus position until a total of approximately 2.5 L of CO2 has the been delivered. The patient assumes the supine position until steady-state equilibrium has been reached, and then scanning is begun. The positional change helps to prevent inadequate distention related to the presence of a fluid channel or bowel kink.
The volume of CO2 dispensed can vary widely not only because of differences in actual colonic volume but also because of varying degrees of reflux through the ileocecal valve, loss around the catheter, and continuous colonic resorption. Therefore, the total volume reading for CO2 delivery has relatively little meaning and can range from 3 L to more than 10 L. It is imperative to acquire the MDCT images during active replacement of CO2 at equilibrium. The supine and prone scans are obtained at end expiration to raise the diaphragm, allowing more room for the splenic flexure and transverse colon.
Although the scout image gives a general indication of distention adequacy, it is unreliable for assessment of the left colon [19] (Fig. 2A, 2B, 2C, 2D). The CT technologists at my institution are trained to recognize inadequate distention, particularly of the sigmoid colon, by online review of 2D transverse images with a wide window setting. This step ensures adequate distention of the left colon and avoids the need for calling the patient back. If focal collapse persists at the same point on both supine and prone scans, a series of right lateral decubitus images are obtained (Fig. 2A, 2B, 2C, 2D), which often yields sufficient information for diagnosis. In less than 1% of patients, segmental evaluation is inadequate despite all efforts. On rare occasion, to complete the screening evaluation we have offered patients same-day flexible sigmoidoscopy without sedation.
|
|
|
|
The CTC scanning protocol at my institution is relatively straightforward. Regardless of continuing advances in CTC technique and interpretation, the established practice of obtaining both supine and prone scans remains firmly entrenched because of the invaluable complementary data obtained. Typical 8- and 16-MDCT scanning factors include 1.25-mm collimation, 1.0- to 1.25-mm reconstruction interval, and 120 kVp. Given the nature of the soft tissue-air interface for polyp detection during CTC, the radiation dose can be markedly less than the usual diagnostic level. To optimize the delivered dose, my colleagues and I use a tube current modulation system (Smart mA, GE Healthcare) that modulates current in both the xy-plane and the z-plane. We set the noise index at 50 and the tube current range at 30-300 mA, which has yielded considerable dose reduction and examinations of consistent quality for diagnosis. For MDCT scanners not equipped with a tube current modulation system, technique with a tube current-time product in the range of 50-75 mAs suffices, except for some morbidly obese patients. Although further dose reduction is a desirable goal for evaluation of adults who do not have symptoms, the small theoretic risk of low-dose radiation exposure is clearly outweighed by the benefit of colorectal cancer screening [20, 21].
With the scanning parameters used at my institution, each series has fewer than 500 images, and fewer than 1,000 images typically are obtained for the total study. These source images are sent to the CTC workstation for advanced modeling and interpretation and to a PACS for storage. To facilitate extracolonic evaluation, in addition to the thin-section source data, a series of contiguous 5-mm images is reconstructed from the supine image data set [5].
CTC Interpretation
2D and 3D Polyp Detection
Both 2D and 3D visualization modes should be used for polyp detection,
although the latter is much easier and more effective for low-prevalence
screening. Interpretive redundancy on different views ensures accurate polyp
detection by adding complementary evaluation. Primary 2D evaluation alone, 3D
being reserved for problem solving, is an inadequate interpretive approach to
low-prevalence CTC screening, primarily because it does not incorporate the
benefit of primary 3D detection. The biphasic interpretive approach used at my
institution emphasizes 3D detection but also retains the added value of 2D
detection. The underlying rationale is simple: The more sensitive but less
specific display (3D endoluminal) is best for initial polyp detection, and the
more specific but less sensitive display (2D) is needed for confirmation of
suspected lesions and, in some cases, auxiliary polyp detection. Although 3D
polyp detection is usually comprehensive, 2D evaluation can be particularly
useful in the presence of abundant adherent feces or segments with partial or
total luminal collapse. For 2D polyp detection, we prefer a window width of
2,000 H centered at 0 H.
|
|
The 3D endoluminal approach works well because polyp conspicuity among the folds is greatly enhanced compared with 2D visualization. The result is a much easier learning curve [27, 28] (Fig. 3A, 3B). At primary 2D evaluation, the ubiquitous haustral folds have a somewhat polypoid appearance, which adds to the challenge of the search for polyps. It seems impractical to struggle to find, or miss, a polyp in 2D when most polyps are obvious on the 3D endoluminal view. Although one solution to poor 2D sensitivity is to incorporate computer-aided detection, this approach has yet to match the performance of primary 3D evaluation [1, 20]. Reviewer fatigue and eyestrain resulting from a 2D polyp search are important issues to consider with high-volume CTC screening. My colleagues and I have found that radiologists generally begin as 2D CTC reviewers but gravitate toward 3D polyp detection as their experience and the volume of polyps detected grow.
Although not yet validated for screening, emerging 3D displays beyond the standard endoluminal projection deserve mention. The virtual dissection, or filet, view has received the most attention [29, 30]. The promise of this display lies in the potential for reducing 3D interpretation time because bidirectional navigation is not needed. The compromise with these novel 3D projections is spatial distortion whereby some polyps become unrecognizable. The effect of this technique on accuracy remains uncertain. My colleagues and I are investigating a variety of primary 3D solutions in a multivendor comparison trial. Optimizing the standard endoluminal field of view to balance mucosal coverage and visual distortion is another potential improvement that is under investigation. This approach appears to allow unidirectional 3D endoluminal fly-through without sacrificing polyp detection (unpublished data).
Interpretive Approach
The CTC interpretation system (V3D, Viatronix) used at my institution is
validated for colorectal screening and is FDA-approved for this purpose
[1,
3]. Software improvements with
this system have resulted in faster and more accurate CTC interpretation
[2,
31]. Although the 3D
capabilities of most other CTC systems were not originally devised for
effective, time-efficient primary 3D evaluation
[32], several systems are
rapidly advancing. It should be only a matter of time before validation and
FDA approval are achieved for other CTC systems.
The supine and prone source images are sent to the CTC software system for interpretation, which segments out the gas-filled bowel and generates an automated centerline. For most screening cases, I begin with 3D endoluminal evaluation because almost all significant polyps are readily detectable with this display. Primary 3D endoluminal review entails bidirectional fly-through of the supine and prone models, which is largely hands-free along the automated centerline and interspersed with manual navigation as needed for interrogating potential abnormalities. My colleagues and I are investigating whether a field of view increased beyond 90° alleviates the need for four complete fly-through views. Flight time from rectum to cecum and vice versa currently is approximately 1 minute in a typical case. Although the CTC system used at my institution allows electronic cleansing, or digital subtraction, of opacified residual luminal fluid [12], my colleagues and I keep this function disabled because we believe that the theoretic benefits are outweighed by the artifacts introduced [9, 31].
|
|
|
|
|
When a nondiminutive lesion is detected and confirmed to be composed of soft tissue, a bookmark is placed. Most true polyps can be verified on the alternate supine or prone view, resulting in increased diagnostic confidence. Linear polyp measurement is not as straightforward as it may seem, because the 2D measurement, which should always be optimized among the multiplanar reconstruction views, tends be an underestimate of polyp size, and the 3D view sometimes produces an overestimate of size [35]. Therefore, my colleagues and I have found it useful to take both measurements into consideration before arriving at a final value. In the future, polyp volume assessment may play an important role in surveillance of unresected lesions [36]. In addition to polyp size, segmental location, morphologic type (pedunculated, sessile, or flat), and diagnostic confidence score are recorded for each polyp. The diagnostic confidence score can provide useful information for program quality assurance [37].
A screening CTC study is considered to have a positive result when a lesion 6 mm or larger is detected, although the polyps of greatest clinical significance are 10 mm or larger. My colleagues and I offer same-day optical colonoscopy to patients who have positive results on CTC, avoiding the need for additional preparation [2, 8]. However, because the procedural risks associated with colonoscopic polypectomy probably outweigh the malignant potential of a small polyp (6-9 mm), we also offer the option of noninvasive CTC surveillance [2]. A consensus proposal [38] suggests a 3-year follow-up interval for CTC surveillance of one or two small polyps, and this recommendation is supported by natural history data [39, 40]. For colonoscopic referral, we provide the gastroenterologist with digital images showing the polyp location on the 3D map, 3D endoluminal projections, and 2D multiplanar reconstructions (Fig. 6A, 6B, 6C). Special note is made of polyps located on the backside of folds, which are more easily missed at colonoscopy [41].
|
|
|
Nearly 90% of screening CTC studies at my institution have negative results
[2], and we recommend routine
screening in 5 years. For a number of reasons, the presence of diminutive
lesions should not be mentioned. First, tiny polyps are not clinically
relevant, yet mentioning them can cause undue anxiety in patients and
referring physicians [1,
38,
40,
42]. Most diminutive
"lesions" detected at CTC cannot be found at subsequent
colonoscopy, representing either false-positive CTC findings or false-negative
colonoscopic findings. To avoid any confusion or false pretenses, we include
the following disclaimer in all CTC reports: "Note: CT colonography is
not intended for the detection of diminutives polyps (
5 mm), the presence
or absence of which will not change the clinical management of the
patient."
Diagnostic Pitfalls
CTC interpretation has a number of potential pitfalls
(Appendix 1). Some pitfalls,
such as prominent and complex folds, diverticular fold thickening, and
shifting of pedunculated polyps, present more of a problem at 2D evaluation.
Other pitfalls, such as annular masses, submucosal or extrinsic lesions, and
impacted diverticula, are more an issue at 3D evaluation. With a biphasic
interpretive approach, most pitfalls are easily recognized because of the
complementary nature of the 2D and 3D displays.
APPENDIX 1: Potential Pitfalls in Interpretation of CT Colonographic Images
|
Diverticular disease can frequently present a challenge in terms of achieving adequate distention and 2D polyp detection, but overall accuracy need not suffer with careful technique and the addition of primary 3D evaluation [43]. Likewise, although flat lesions are more challenging to detect initially, the sensitivity of CTC still appears adequate [44]. In addition, histologically advanced flat lesions appear to be rare in the screening population in the United States and do not represent a significant limitation of CTC screening [44, 45]. Carpet lesions are a subset of flat lesions that, despite their large linear dimensions, can be relatively subtle on CTC. My colleagues and I have found that classic large carpet lesions are rare but often prove to be villous adenomas, whereas flat lesions smaller than 3 cm tend to be nonneoplastic hyperplastic lesions.
An interesting observation is that most polyps of significant size missed with our CTC approach turn out to be nonadenomatous (predominately hyperplastic) even though such lesions are considerably outnumbered by adenomas at this size [46]. An isolated thickened fold can present a diagnostic challenge on CTC but rarely if ever represents a significant pathologic condition if it is smooth and uniform at 3D evaluation. Other pitfalls that we have encountered on a number of occasions relate to inverted appendiceal stumps, submucosal vascular blebs, the ileocecal valve, and the presence of the rectal catheter [34, 47-49].
Conclusion
With continued improvements in bowel preparation, colonic distention, and CTC interpretation, the results of CTC screening at my institution have exceeded initial expectations. The significant reduction in false-positive results has led to a 90% positive predictive value and has decreased the CTC test-positive rate to about 12% [2]. The increase in specificity has not been at the expense of decreased sensitivity. A direct comparison of CTC and optical colonoscopy programs showed similar detection rates for advanced neoplasia (Kim DH et al., presented at the 2006 meeting of the European Society of Gastrointestinal and Abdominal Radiology/Society of Gastrointestinal Radiologists). That the number of invasive procedures and polypectomies needed to achieve the same goal is many times less with the CTC approach shows that this examination is an effective and efficient filter for primary screening. Once national insurance coverage for CTC screening is in place, this procedure is poised to become a major practice component of our specialty. If the procedural details are properly addressed, CTC screening may have a profound effect on screening for and prevention of colorectal cancer.
References
This article has been cited by other articles:
![]() |
S. D. Pearson, A. B. Knudsen, R. W. Scherer, J. Weissberg, and G. S. Gazelle Assessing The Comparative Effectiveness Of A Diagnostic Technology: CT Colonography Health Aff., November 1, 2008; 27(6): 1503 - 1514. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Van Uitert, R. M. Summers, J. M. White, K. K. Deshpande, J. R. Choi, and P. J. Pickhardt Temporal and Multiinstitutional Quality Assessment of CT Colonography Am. J. Roentgenol., November 1, 2008; 191(5): 1503 - 1508. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. H. Dachman, K. B. Kelly, M. P. Zintsmaster, R. Rana, S. Khankari, J. D. Novak, A. N. Ali, A. Qalbani, and J. G. Fletcher Formative Evaluation of Standardized Training for CT Colonographic Image Interpretation by Novice Readers Radiology, October 1, 2008; 249(1): 167 - 177. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Park, S. S. Lee, J. K. Kim, M.-J. Kim, H. J. Kim, S. Y. Kim, M.-Y. Kim, A. Y. Kim, and H. K. Ha Volume Rendering with Color Coding of Tagged Stool during Endoluminal Fly-through CT Colonography: Effect on Reading Efficiency Radiology, September 1, 2008; 248(3): 1018 - 1027. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Pickhardt, A. D. Lee, A. J. Taylor, S. J. Michel, T. C. Winter, A. Shadid, R. J. Meiners, P. J. Chase, J. L. Hinshaw, J. G. Williams, et al. Primary 2D Versus Primary 3D Polyp Detection at Screening CT Colonography Am. J. Roentgenol., December 1, 2007; 189(6): 1451 - 1456. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |