|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Original Research |
1 Department of Radiology, Clinical Research Institute, and Institute of
Radiation Medicine, Seoul National University Hospital, Seoul National
University Medical Research Center, 28, Yongon-dong, Chongno-gu, Seoul,
100-744, Korea.
2 Department of Radiology, College of Medicine, Hanyang University,
Seongdong-gu, Seoul, Korea.
3 Department of Pathology, Seoul National University Hospital, Seoul,
Korea.
Received January 8, 2008;
accepted after revision May 23, 2008.
Address correspondence to N. Cho
(nariya{at}radiol.snu.ac.kr).
Abstract
|
|
|---|
MATERIALS AND METHODS. We retrospectively reviewed 3,563 lesions con secutively evaluated with sonographically guided core biopsy between January 2002 and June 2006. Histologic analysis yielded ADH in 60 of the 3,563 lesions (1.7%). The rate of underestimation of ADH was determined by dividing the number of lesions that proved to be carcinoma at surgical excision by 44, the total number of lesions evaluated with excisional biopsy. Clinical, sonographic, and core biopsy features were analyzed to identify factors that affect the rate of underestimation of ADH.
RESULTS. The rate of underestimation of ADH was found to be 48% (21 of 44 lesions). Underestimation of ADH was significantly less frequent for lesions evaluated with 11-gauge vacuum-assisted biopsy than for lesions evaluated with 14-gauge automated gun biopsy (22% [four of 18 lesions] vs 65% [17 of 26 lesions], p = 0.012). The other clinical, sonographic, and biopsy features examined did not affect the rate of underestimation of ADH.
CONCLUSION. For sonographically guided core biopsy of the breast,
the rate of underestimation of ADH was 48%. This rate was lower for lesions
evaluated with 11-gauge vacuum-assisted biopsy (22%) than for those evaluated
with 14-gauge automated gun biopsy (65%). This finding was particularly true
of smaller lesions (
2.0 cm) and for lesions of the mass-only type.
Keywords: biopsy breast breast neoplasms diagnosis sonography technology
|
|
|---|
Atypical ductal hyperplasia (ADH) is the most common high-risk lesion of the breast. It is defined as a ductal hyperplastic lesion that has cellular atypia and structural rigidity suggesting ductal carcinoma in situ (DCIS) but involving only one duct profile or an area less than 2 mm in diameter [4]. Pathologists have considerable interobserver variability in terms of determining whether a lesion is ADH or DCIS [5], and ADH lesions frequently coexist with DCIS or invasive carcinoma [6]. For these reasons, lesions determined to be ADH at core needle biopsy often are found to be malignant tumors at subsequent surgery [7, 8]. Reports [9–16] indicate a 20–56% rate of underestimation of ADH at stereotactic 14-gauge automated core biopsy and a 11–27% rate at stereotactic 11-gauge vacuum-assisted biopsy. Because most lesions containing ADH have calcifications, underestimation at percutaneous biopsy is most common for calcific lesions examined with stereotactic biopsy [17]. Few reports have addressed the rate of underestimation of ADH and factors affecting this rate at sonographically guided core biopsy [18–21]. The purpose of this study was to determine the rate of underestimation of ADH at sonographically guided core biopsy of the breast and to identify the factors involved.
|
|
|---|
Sonographically guided percutaneous biopsy yielded benign histologic findings on 2,534 of the 3,563 lesions (71%), high-risk findings on 252 lesions (7%), and malignant findings on 777 lesions (22%). Biopsy of 60 of the 3,563 lesions (1.7%) yielded a finding of ADH. Among the 60 women with these lesions, seven women were lost to follow-up, and nine women underwent one or two follow-up imaging examinations 6–32 months after detection without undergoing surgery. No malignancy was found in the follow-up group. Forty-four women with 44 lesions (26 who underwent 14-gauge automated gun biopsy, 18 who underwent 11-gauge vacuum-assisted biopsy) who underwent surgical excision constituted the study group. This study was approved by the institutional review board, which waived the requirement for informed consent.
Biopsy Procedure
All biopsies were guided by high-resolution sonography performed with a
unit equipped with a 10- or 12-MHz linear transducer (Voluson 730, GE-Kretz;
HDI 5000, Advanced Technology Laboratories). Patients were in the supine or
oblique supine position. A 14-gauge automated gun (Pro-Mag 2.2, Manan Medical
Products) was used on 2,463 lesions (69%) and an 11-gauge vacuum-assisted
device (Mammotome, Ethicon Endo-Surgery) on 1,100 lesions (31%)
(Table 1).
|
Radiologists performing biopsies were primarily responsible for choosing the biopsy device used. Automated gun biopsy was preferred for multifocal lesions and for lesions in the subareolar or axillary area. The 11-gauge vacuum-assisted device was preferred for intraductal lesions and solid nodules smaller than 10 mm in diameter. When automated gun biopsy was used, needle insertion was immediately proximal to the lesion. After the lesion capsule was pierced, the gun was fired into the lesion for automatic sampling of a small core. After the device was fired, longitudinal and transverse images of needles located in the center of the mass were obtained. Our protocol required that at least four nonfragmented samples be obtained with the automated gun biopsy. When a vacuum-assisted biopsy device was used, a small skin incision was made, and the needle was inserted either through or directly subjacent to the lesion. The needle was manually rotated in a circumferential clockwise manner for sampling of both the target lesion and adjacent tissues. Our protocol required removal of all evidence of the target lesion during vacuum-assisted biopsy.
An average of five core samples (range, three to eight) was obtained with the 14-gauge automated gun and 14 (range, seven to 33) with the 11-gauge vacuum-assisted device. Approximately 20% of biopsies were performed by one of two attending radiologists with 4–7 years of experience in breast sonography and intervention. The other biopsies were performed by one of four fellows, who performed their first five to 10 biopsies under the supervision of an attending radiologist.
Assessment of Variables
Lesion variables, including size (maximal diameter on sonograms), type
(mass with calcifications or mass only according to mammographic findings),
and BI-RADS final assessment category, were determined by two radiologists in
consensus before biopsy. According to the probability of malignancy,
subcategories of category 4 were described as 3–10% in 4a (low level of
suspicion), 11–50% in 4b (intermediate suspicion), and 51–94% in
4c (moderate suspicion). Biopsy variables including the biopsy method used and
number of core specimens retrieved were recorded during biopsy procedures.
Histologic results of core biopsy were compared with those obtained during
subsequent surgery. Coexistent pathologic lesions and the presence of a second
high-risk lesion associated with ADH were evaluated by review of histology
reports at final excision.
Postbiopsy Management
Patients with a biopsy result of malignancy (invasive ductal carcinoma,
DCIS, invasive lobular carcinoma, or malignant phyllodes tumor) underwent
surgical excision. Surgical excision was recommended for patients with a
high-risk lesion (ADH, atypical papillary tumor, radial scar, benign phyllodes
tumor, atypical lobular hyperplasia, lobular carcinoma in situ, or a
mucocele-like tumor). When a lesion with a benign pathologic result (all
lesions not malignant or high-risk lesions) was determined to have concordant
imaging findings, 6-, 12-, and 24-month follow-up imaging examinations were
recommended. If a lesion with a benign pathologic result had a highly
suspicious sonographic finding, surgical excision was recommended despite the
benign pathologic result.
Data Analysis
Underestimation of ADH was defined as having occurred when the finding of
ADH at core biopsy was changed to carcinoma (DCIS or invasive ductal
carcinoma) at surgery. The rate of underestimation of ADH was determined by
dividing the number of lesions proved DCIS or invasive carcinoma at excision
by the total number of lesions for which excisional biopsy was performed. We
also evaluated whether underestimation of ADH was affected by a family or
personal history of breast cancer, lesion size, lesion type, final assessment
category, biopsy method, number of core specimens, and the presence of a
high-risk lesion in the surgical specimen. To identify factors that affected
underestimation of ADH, we compared the rates of underestimation of lesions
with and without factors related to lesion characteristics. Analysis was
performed with the chi-square test, Fisher's exact test, and Student's
t test in the SPSS program (version 10.0 for Microsoft Windows,
SPSS). Values of p < 0.05 were considered to indicate a
significant difference.
|
|
|---|
Table 2 compares the accurate diagnoses (n = 23) and underestimations (n = 21) according to patient, lesion, and biopsy variables. Women in the accurate diagnosis group were younger than those in the underestimation group (mean age, 46 vs 52 years; p = 0.016). Seventeen of the 26 ADH lesions (65%) found with 14-gauge automated gun biopsy were upgraded to carcinoma (10 DCIS, seven invasive ductal carcinomas), and four of the 18 ADH lesions (22%) found with 11-gauge vacuum-assisted biopsy were upgraded to carcinoma (two DCIS, two invasive ductal carcinomas). The underestimation rate for 11-gauge vacuum-assisted biopsy (22%) was significantly lower than that for 14-gauge automated gun biopsy (65%) (p = 0.012).
|
No difference was found between the accurate diagnosis and underestimation groups in terms of family or personal history of breast cancer (p = 1.0), lesion size (p = 0.272), lesion type (p = 0.761), BI-RADS category (p = 0.559), number of core specimens (p = 0.108), or presence of combined high-risk lesions (p = 0.526). The accurate diagnosis group had three papillary lesions, one radial scar, and two mucocele-like lesions; the underestimation group had four papillary lesions, one radial scar, and one lobular carcinoma in situ.
The underestimation rates for 14-gauge automated gun biopsy and 11-gauge
vacuum-assisted biopsy were compared with respect to lesion characteristics
(Table 3). The rate of
underestimation of ADH at 14-gauge automated gun biopsy was higher than that
of 11-gauge vacuum-assisted biopsy for smaller (
2.0 cm) lesions (61% [14
of 23 lesions] versus 8% [one of 12], p = 0.004)] and mass-only
lesions (67% [14 of 21] versus 0% (zero of seven), p = 0.009). No
difference was observed between the underestimation rates of the two biopsy
methods for larger (
2.1 cm) lesions (p = 0.464) or masses with
calcification (p = 0.734). There also were no differences related to
BI-RADS category.
|
|
|
|---|
The outcome of percutaneous biopsy of the breast depends mainly on lesion
type and the amount of sample obtained. In this study, use of an 11-gauge
vacuum-assisted device was associated with a lower rate of underestimation of
ADH compared with 14-gauge core biopsy. This finding was notable for small
lesions (
2.0 cm) (8% [one of 12 lesions] vs 61% [14 of 23], p =
0.004) and for mass-only lesions (0% [zero of seven lesions] vs 67% [14 of
21], p = 0.009). Many studies
[9–12]
of stereotactic biopsy have shown that 11-gauge vacuum-assisted devices remove
larger amounts of tissue than do 14-gauge core biopsy devices and that use of
11-gauge devices is associated with a lower rate of underestimation of ADH.
These findings may be applicable to sonographically guided biopsy. Calcific
lesions, in which ADH is commonly found, have a heterogeneous and
discontinuous distribution; thus larger sample volumes are needed than for
mass lesions [17,
22]. In one stereotactic
biopsy series [23], the rate
of underestimation of ADH was higher for masses than for microcalcifications.
Our results, however, suggest that use of 11-gauge vacuum-assisted biopsy
reduces the rate of underestimation of masses alone but not of masses with
calcifications at sonographically guided biopsy. Because calcifications are
barely visible at sonography, calcifications remaining after biopsy were
thought be the cause of underestimation.
The partial volume averaging effect is a well-known cause of inadequate targeting during sonographically guided biopsy, notably of small lesions. With vacuum-assisted devices, samples can be contiguous and larger than with the 14-gauge gun, and all evidence of lesions can be removed. These features overcome the partial volume averaging effect of small lesions and min i mize the residual lesions that cause histo logic underestimation. Sonographically guided vacuum-assisted removal of all sonographic evidence of a lesion was associated with a 0% (zero of 29 lesions) rate of underestimation of ADH in one study [19]. Even complete removal of all mammographic evidence at stereotactic 11-gauge vacuum-assisted biopsy, however, revealed residual lesion during surgical excision [24] and had an 8% (three of 36 lesions) rate of underestimation of ADH [16].
Although reduced underestimation with use of an 11-gauge vacuum-assisted device is explained by larger sample volumes, there is a tendency to obtain more cores for larger lesions or lesions that are difficult to target. Thus the number of specimens obtained appears not to be correlated with a lower rate of underestimation (Table 2). These results are similar to those of a previous study [16], in which the investigators found that specimen numbers per lesion did not correlate with underestimation but that complete lesion removal did correlate with degree of underestimation. These findings indicate that targeting precision is more important than sample numbers. Further studies with more cases are needed to determine whether complete lesion removal at sonographically guided 11-gauge vacuum-assisted biopsy can reduce the rate of underestimation of ADH.
We also evaluated whether finding a second high-risk lesion at core biopsy was related to rate of underestimation of ADH, hoping to find a histologic feature at core biopsy that could serve as a marker for high risk. We found no difference between the accurate diagnosis and underestimation groups in terms of presence of a second high-risk lesion at core biopsy (Table 2).
Our study had several limitations. First, biopsies were performed by one of six radiologists with different levels of ex pe rience. Although the first five to 10 biopsies by fellows were performed under the supervision of an attending radiologist, the training process, especially concerning accurate targeting, might have been incomplete. Second, decisions concerning the biopsy device used were not randomized. A 14-gauge automated gun was preferred for multifocal lesions and for lesions in the subareolar or axillary area, and an 11-gauge vacuum-assisted device was preferred for intraductal lesions and solid nodules smaller than 10 mm, for which the potential benefits of use of the vacuum-assisted device had already been suggested. Third, our biopsy protocols involved removal of all evidence of lesions targeted during 11-gauge vacuum-assisted biopsy and acquisition of at least four nonfragmented samples during 14-gauge automated gun biopsy, and these factors might have affected the rate of underestimation of ADH.
For sonographically guided core biopsy of the breast, the rate of underestimation of ADH was found to be 48%. This rate was lower for 11-gauge vacuum-assisted biopsy (22%) than for 14-gauge automated gun biopsy (65%), notably for lesions 20 mm or smaller and for lesions of the mass-only type. These findings, however, do not mean that we prefer vacuum-assisted biopsy to automated gun biopsy for all sonographic lesions in clinical practice. The decision about which biopsy method to use also depends on procedure-related complications, cost-effectiveness, and time.
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |